C-28
L90 Line Current Differential System
GE Multilin
C.7 LOGICAL NODES
APPENDIX C
C
PUPF: Underpower factor
---
PVOC: Voltage controlled time overcurrent
---
PVPH: Volts per Hz
---
PZSU: Zero speed or underspeed
---
Q: LOGICAL NODES FOR POWER QUALITY EVENTS
QFVR: Frequency variation
---
QITR: Current transient
---
QIUB: Current unbalance variation
---
QVTR: Voltage transient
---
QVUB: Voltage unbalance variation
---
QVVR: Voltage variation
---
R: LOGICAL NODES FOR PROTECTION-RELATED FUNCTIONS
RADR: Disturbance recorder channel analogue
---
RBDR: Disturbance recorder channel binary
---
RBRF: Breaker failure
---
RDIR: Directional element
---
RDRE: Disturbance recorder function
Yes
RDRS: Disturbance record handling
---
RFLO: Fault locator
Yes
RMXU: Differential measurements
---
RPSB: Power swing detection/blocking
Yes
RREC: Autoreclosing
Yes
RSYN: Synchronism-check or synchronizing
Yes
S: LOGICAL NODES FOR SENSORS AND MONITORING
SARC: Monitoring and diagnostics for arcs
---
SCBR: Circuit breaker supervision
---
SIMG: Insulation medium supervision (gas)
---
SIML: Insulation medium supervision (liquid)
---
SLTC: Tap changer supervision
---
SOPM: Supervision of operating mechanism
---
SPDC: Monitoring and diagnostics for partial discharges
---
SPTR: Power transformer supervision
---
SSWI: Circuit switch supervision
---
STMP: Temperature supervision
---
SVBR: Vibration supervision
---
T: LOGICAL NODES FOR INSTRUMENT TRANSFORMERS
TANG: Angle
---
TAXD: Axial displacement
---
TCTR: Current transformer
---
TDST: Distance
---
TFLW: Liquid flow
---
TFRQ: Frequency
---
TGSN: Generic sensor
---
THUM: Humidity
---
TLVL: Media level
---
TMGF: Magnetic field
---
TMVM: Movement sensor
---
Table C–1: IEC 61850 LOGICAL NODES (Sheet 3 of 4)
NODES
UR-FAMILY
Содержание UR Series L90
Страница 14: ...xiv L90 Line Current Differential System GE Multilin 0 1 BATTERY DISPOSAL 0 BATTERY DISPOSAL 0 ...
Страница 68: ...2 34 L90 Line Current Differential System GE Multilin 2 4 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Страница 138: ...4 30 L90 Line Current Differential System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 604: ...9 58 L90 Line Current Differential System GE Multilin 9 6 FAULT LOCATOR 9 THEORY OF OPERATION 9 ...
Страница 652: ...A 16 L90 Line Current Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 772: ...B 120 L90 Line Current Differential System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 802: ...C 30 L90 Line Current Differential System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Страница 812: ...D 10 L90 Line Current Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Страница 824: ...E 12 L90 Line Current Differential System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...
Страница 834: ...F 10 L90 Line Current Differential System GE Multilin F 3 WARRANTY APPENDIX F F ...
Страница 846: ...xii L90 Line Current Differential System GE Multilin INDEX ...