GE Power Management
469 Motor Management Relay
2-7
2 INSTALLATION
2.1 MECHANICAL
2
Table 2–1: 469 TERMINAL LIST
A01
RTD #1 HOT
D21
ASSIGNABLE SW. 03
A02
RTD #1 COMPENSATION
D22
ASSIGNABLE SW. 04
A03
RTD RETURN
D23
SWITCH COMMON
A04
RTD #2 COMPENSATION
D24
24 V DC
A05
RTD #2 HOT
D25
COMPUTER RS485 +
A06
RTD #3 HOT
D26
COMPUTER RS485 –
A07
RTD #3 COMPENSATION
D27
COMPUTER RS485 COMMON
A08
RTD RETURN
E01
R1 TRIP NC
A09
RTD #4 COMPENSATION
E02
R1 TRIP NO
A10
RTD #4 HOT
E03
R2 AUXILIARY COMMON
A11
RTD #5 HOT
E04
R3 AUXILIARY NC
A12
RTD #5 COMPENSATION
E05
R3 AUXILIARY NO
A13
RTD RETURN
E06
R4 ALARM COMMON
A14
RTD #6 COMPENSATION
E07
R5 BLOCK START NC
A15
RTD #6 HOT
E08
R5 BLOCK START NO
A16
ANALOG OUT COMMON –
E09
R6 SERVICE COMMON
A17
ANALOG OUT 1 +
E10
not used
A18
ANALOG OUT 2 +
E11
COIL SUPER
A19
ANALOG OUT 3 +
E12
469 DRAWOUT INDICATOR
A20
ANALOG OUT 4 +
F01
R1 TRIP COMMON
A21
ANALOG SHIELD
F02
R2 AUXILIARY NO
A22
ANALOG INPUT 24 V DC POWER
F03
R2 AUXILIARY NC
A23
ANALOG INPUT 1 +
F04
R3 AUXILIARY COMMON
A24
ANALOG INPUT 2 +
F05
R4 ALARM NO
A25
ANALOG INPUT 3 +
F06
R4 ALARM NC
A26
ANALOG INPUT 4 +
F07
R5 BLOCK START COMMON
A27
ANALOG INPUT COMMON –
F08
R6 SERVICE NO
B01
RTD SHIELD
F09
R6 SERVICE NC
B02
AUXILIARY RS485 +
F10
not used
B03
AUXILIARY RS485 –
F11
COIL SUPERVISION –
B04
AUXILIARY RS485 COMMON
F12
469 DRAWOUT INDICATOR
C01
G01
PHASE VT NEUTRAL
C02
ACCESS –
G02
PHASE A VT •
C03
469 UNDER TEST +
G03
DIFFERENTIAL A CT •
C04
469 UNDER TEST –
G04
DIFFERENTIAL B CT •
D01
RTD #7 HOT
G05
DIFFERENTIAL C CT •
D02
RTD #7 COMPENSATION
G06
PHASE A CT •
D03
RTD RETURN
G07
PHASE B CT •
D04
RTD #8 COMPENSATION
G08
PHASE C CT •
D05
RTD #8 HOT
G09
1A/5A GROUND CT •
D06
RTD #9 HOT
G10
50:0.025 GROUND CT •
D07
RTD #9 COMPENSATION
G11
FILTER GROUND
D08
RTD RETURN
G12
SAFETY GROUND
D09
RTD #10 COMPENSATION
H01
PHASE B VT •
D10
RTD #10 HOT
H02
PHASE C VT •
D11
RTD #11 HOT
H03
DIFFERENTIAL A CT
D12
RTD #11 COMPENSATION
H04
DIFFERENTIAL B CT
D13
RTD RETURN
H05
DIFFERENTIAL C CT
D14
RTD #12 COMPENSATION
H06
PHASE A CT
D15
RTD #12 HOT
H07
PHASE B CT
D16
STARTER STATUS
H08
PHASE C CT
D17
EMERGENCY RESTART
H09
1A/5A GROUND CT
D18
REMOTE RESET
H10
50:0.025 GROUND CT
D19
ASSIGNABLE SW. 01
H11
CONTROL POWER –
D20
ASSIGNABLE SW. 02
H12
CONTROL POWER +
Содержание MOTOR MANAGEMENT RELAY 469
Страница 2: ......
Страница 4: ......
Страница 12: ......
Страница 22: ......
Страница 50: ......
Страница 142: ......
Страница 240: ......
Страница 254: ......
Страница 272: ......
Страница 286: ......
Страница 290: ......
Страница 294: ......
Страница 298: ......
Страница 300: ......
Страница 302: ......