5-28
469 Motor Management Relay
GE Power Management
5.8 DIAGNOSTICS
5 ACTUAL VALUES
5
5.8.2 FLASH MESSAGES
Flash messages are warning, error, or general information messages that are temporarily displayed in
response to certain key presses. These messages are intended to assist with navigation of the 469 messages
by explaining what has happened or by prompting the user to perform certain actions.
•
NEW SETPOINT HAS BEEN STORED:
This message appear each time a setpoint has been altered and stored
as shown on the display.
•
ROUNDED SETPOINT HAS BEEN STORED:
A setpoint value entered with the numeric keypad may be between
valid setpoint values. The 469 detects this condition and stores a value that has been rounded to the near-
est valid setpoint value. To find the valid range and step for a given setpoint, simply press
while the
setpoint is being displayed.
•
OUT OF RANGE! ENTER: #### - ##### BY #:
If an entered setpoint value that is outside of the acceptable
range of values, the 469 displays this message, substituting the proper values for that setpoint. An appro-
priate value may then be entered.
•
ACCESS DENIED, SHORT ACCESS SWITCH
: In order to store any setpoint values, the access switch must be
shorted. If this message appears and it is necessary to change a setpoint, short access terminals C1 and
C2.
•
ACCESS DENIED, ENTER PASSCODE:
The 469 has a passcode security feature. If that feature has been
enabled, not only do the access switch terminals have to be shorted, but the passcode must also be
entered. If the correct passcode has been lost or forgotten, contact the factory with the encrypted access
code. See Section 4.2.1: PASSCODE on page 4–4 for passcode features.
•
INVALID PASSCODE ENTERED
: If an invalid passcode is entered for passcode security feature, this message
will flash on the display.
•
NEW PASSCODE HAS BEEN ACCEPTED:
This message will appear as an acknowledge that the new passcode
has been accepted when changing the passcode for the passcode security feature.
•
PASSCODE SECURITY NOT ENABLED, ENTER 0:
The passcode security feature is disabled whenever the pass-
code is zero (factory default). Any attempts to enter a passcode when the feature is disabled displays this
flash message. It prompts the user to enter
0
as the passcode. When this has been done, the feature may
be enabled by entering a non-zero passcode.
Table 5–5: FLASH MESSAGES
NEW SETPOINT HAS
BEEN STORED
ROUNDED SETPOINT
HAS BEEN STORED
OUT OF RANGE! ENTER:
####-##### by #
ACCESS DENIED,
SHORT ACCESS SWITCH
ACCESS DENIED,
ENTER PASSCODE
INVALID PASSCODE
ENTERED!
NEW PASSCODE
HAS BEEN ACCEPTED
PASSCODE SECURITY
NOT ENABLED, ENTER 0
PLEASE ENTER A
NON-ZERO PASSCODE
SETPOINT ACCESS IS
NOW PERMITTED
SETPOINT ACCESS IS
NOW RESTRICTED
DATE ENTRY WAS
NOT COMPLETE
DATE ENTRY
OUT OF RANGE
TIME ENTRY WAS
NOT COMPLETE
TIME ENTRY
OUT OF RANGE
NO TRIPS OR ALARMS
TO RESET
RESET PERFORMED
SUCCESSFULLY
ALL POSSIBLE RESETS
HAVE BEEN PERFORMED
CONDITION IS PRESENT
RESET NOT POSSIBLE
ARE YOU SURE? PRESS
[ENTER] TO VERIFY
PRESS [ENTER] TO ADD
DEFAULT MESSAGE
DEFAULT MESSAGE
HAS BEEN ADDED
DEFAULT MESSAGE
LIST IS FULL
PRESS [ENTER] TO
REMOVE MESSAGE
DEFAULT MESSAGE
HAS BEEN REMOVED
DEFAULT MESSAGES
6 TO 20 ARE ASSIGNED
INPUT FUNCTION
ALREADY ASSIGNED
INVALID SERVICE
CODE ENTERED
KEY PRESSED IS
INVALID HERE
DATA CLEARED
SUCCESSFULLY
TOP OF PAGE
END OF PAGE
TOP OF LIST
END OF LIST
MOTOR STARTING
yy
1
yy
2
yy
3
yy
4
yy
5
yy
6
yy
[.] KEY IS USED TO
ADVANCE THE CURSOR
NO ALARMS ACTIVE
NO START BLOCKS
ACTIVE
THIS FEATURE NOT
PROGRAMMED
HELP
Содержание MOTOR MANAGEMENT RELAY 469
Страница 2: ......
Страница 4: ......
Страница 12: ......
Страница 22: ......
Страница 50: ......
Страница 142: ......
Страница 240: ......
Страница 254: ......
Страница 272: ......
Страница 286: ......
Страница 290: ......
Страница 294: ......
Страница 298: ......
Страница 300: ......
Страница 302: ......