D-4
L90 LINE CURRENT DIFFERENTIAL SYSTEM – INSTRUCTION MANUAL
REVISION HISTORY
APPENDIX D: MISCELLANEOUS
D
Table D-4: Major changes for L90 manual version AE1 (English)
Table D-5: Major changes for L90 manual version AC1 (English)
11-5
Added Copy Settings to Other Device section
Page
Description
---
General revision
---
Added routable GOOSE content in chapters 2 and 5
3-35
Updated RS422 and Fiber Interface Connection figure for the clock channels (from 7a and 7b to 1a and 1b)
4-
Added Engineer content
5-
Updated IEC 61850 content
A-
Updated FlexAnalog table for most UR products
Page
Description
---
General revision. Added online help and updated generic online help.
---
Deleted EAC logo from title page and deleted EAC certification from Approvals specifications because document not
translated into Russian
---
Updated Breaker Arcing Current content, including FlexLogic operands table, settings, logic diagram, actual values, Modbus
memory map
---
Updated Synchrocheck content including settings, logic diagram, actual values, and number of elements in interface chapter,
FlexLogic operands table, settings, actual values, FlexAnalog table, features per product table, Modbus memory map, IMD
tables
---
Updated Fault Report content in Settings and Actual Values chapters. Added Estimation of Fault Resistance section to Theory
of Operation chapter. Updated Modbus memory map. Increased number of elements to four.
---
Added Volts per Hertz element to product description, single line diagram, specifications, FlexLogic operand table,
FlexElements table, settings chapter, actual values chapter, FlexAnalog table, Features per Product table, Modbus memory
map, IMD tables
---
Added (Source) Voltage Harmonics and THD Metering content to description, specifications, actual values, FlexElements table,
Modbus memory map, IMD table
---
Added Source Current THD and Harmonics content to specifications, actual values, Modbus memory map
---
Added Compensated Overvoltage content to product description, specifications, FlexLogic operands table, settings, features
per product table, Modbus memory map, IMD tables
---
Updated number of Breaker Restrike elements, increasing from two to four, in FlexLogic operands table, settings, features per
product table, Modbus memory map
---
Added one FlexLogic operand for POTT as per L60
---
Updated Breaker Failure number from 2 to 4 in FlexLogic operands table, settings, feature per product table, Modbus memory
map
---
Updated Neutral Time Overcurrent (TOC) number from 6 to 4 in FlexLogic operands table, settings, features per product table,
Modbus memory map
---
Updated Phase Time Overcurrent (TOC) number from 6 to 4 in FlexLogic operands table, settings, features per product table,
Modbus memory map
---
Updated number of Restricted Ground Fault elements in FlexLogic operands table, settings, actual values, features per
product table, Modbus memory map
---
Updated number of Disconnect Breaker Switch elements from 16 to 24 in FlexLogic operands table, settings, features per
product table, Modbus memory map
2-
Updated several specifications, such as TOC, IOC, number of FlexLogic lines
4-30
Added FlexLogic Design and Monitoring using Engineer section to end of Interfaces chapter
5-38
Added PRT FUNCTION settings in Network section to enable/disable each Ethernet port
5-50
Updated IEC 61850 section
5-62
Added Support for Routable GOOSE section
5-195
Updated number of FlexLogic lines from 512 to 1024 in FlexLogic Equation Editor settings section
5-225
Updated Zone 1 and 2 ground distance logic diagrams to include IG
11-1
Added Monitoring section
Page
Description
Содержание L90
Страница 14: ...1 4 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL FOR FURTHER ASSISTANCE CHAPTER 1 INTRODUCTION 1 ...
Страница 68: ...2 54 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL SPECIFICATIONS CHAPTER 2 PRODUCT DESCRIPTION 2 ...
Страница 136: ...3 68 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL CONNECT TO D400 GATEWAY CHAPTER 3 INSTALLATION 3 ...
Страница 224: ...4 88 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL FLEXLOGIC DESIGN USING ENGINEER CHAPTER 4 INTERFACES 4 ...
Страница 692: ...6 36 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL PRODUCT INFORMATION CHAPTER 6 ACTUAL VALUES 6 ...
Страница 708: ...7 16 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL TARGETS MENU CHAPTER 7 COMMANDS AND TARGETS 7 ...
Страница 742: ...9 6 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL TESTING CHAPTER 9 COMMISSIONING 9 ...
Страница 804: ...10 62 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL FAULT LOCATOR CHAPTER 10 THEORY OF OPERATION 10 ...
Страница 872: ...C 6 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL COMMAND LINE INTERFACE APPENDIX C COMMAND LINE INTERFACE C ...
Страница 878: ...D 6 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL REVISION HISTORY APPENDIX D MISCELLANEOUS D ...
Страница 882: ...iv L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL ABBREVIATIONS ...
Страница 900: ...xviii L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL INDEX ...