CHAPTER 6: ACTUAL VALUES
PRODUCT INFORMATION
L90 LINE CURRENT DIFFERENTIAL SYSTEM – INSTRUCTION MANUAL
6-35
6
The shown data is illustrative only. A modification file number of 0 indicates that, currently, no modifications have been
installed.
6.6.2.2 Graphical front panel
ACTUAL VALUES
PRODUCT INFO
FIRMWARE REVISIONS
The shown data is illustrative only. A modification file number of 0 indicates that, currently, no modifications have been
installed. The date format reflects the format specified for the clock and can vary from that shown here.
MODIFICATION FILE
NUMBER: 0
Range: 0 to 65535 (ID of the MOD FILE)
Value is 0 for each standard firmware release.
BOOT PROGRAM
REVISION: 7.01
Range: 0.00 to 655.35
Revision number of the boot program firmware.
FRONT PANEL PROGRAM
REVISION: 2.01
Range: 0.00 to 655.35
Revision number of front panel program firmware.
COMPILE DATE:
2016/09/15 04:55:16
Range: YYYY/MM/DD HH:MM:SS
Date and time when product firmware was built.
BOOT DATE:
2013/09/15 16:41:32
Range: YYYY/MM/DD HH:MM:SS
Date and time when the boot program was built.
FPGA PROGRAM
REVISION: 02.02
Range: 0.00 to 655.35
Revision number for FPGA.
FPGA DATE:
2016/09/15 16:41:32
Range: YYYY/MM/DD HH:MM:SS
Date and time when the FPGA was built.
FIRMWARE REVISIONS
L90 Relay
REVISION: 7.6x
Range: 0.00 to 655.35
Revision number of the application firmware.
MODIFICATION FILE
NUMBER: 0
Range: 0 to 65535 (ID of the MOD FILE)
Value is 0 for each standard firmware release.
BOOT PROGRAM
REVISION: 7.01
Range: 0.00 to 655.35
Revision number of the boot program firmware.
COMPILE DATE:
2017/06/15 04:55:16
Range: YYYY/MM/DD HH:MM:SS
Date and time when product firmware was built.
BOOT DATE:
2016/09/15 16:41:32
Range: YYYY/MM/DD HH:MM:SS
Date and time when the boot program was built.
GFP PROGRAM
REVISION: 7.60
Range: 0.00 to 655.35
Revision number of front panel program firmware.
GFP COMPILE DATE:
2017/03/03 12:58:00
Range: YYYY/MM/DD HH:MM:SS
Date/time when graphical front panel firmware built.
GFP BOOT PROGRAM
REVISION: 1.00
Range: 0.00 to 655.35
Revision number of panel boot program firmware.
GFP BOOT COMP. DATE:
2017/03/03 12:58:00
Range: YYYY/MM/DD HH:MM:SS
Date/time when panel boot program was built.
FPGA PROGRAM
REVISION: 02.02
Range: 0.00 to 655.35
Revision number for FPGA.
FPGA DATE:
2016/09/15 16:41:32
Range: YYYY/MM/DD HH:MM:SS
Date and time when the FPGA was built.
Содержание L90
Страница 14: ...1 4 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL FOR FURTHER ASSISTANCE CHAPTER 1 INTRODUCTION 1 ...
Страница 68: ...2 54 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL SPECIFICATIONS CHAPTER 2 PRODUCT DESCRIPTION 2 ...
Страница 136: ...3 68 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL CONNECT TO D400 GATEWAY CHAPTER 3 INSTALLATION 3 ...
Страница 224: ...4 88 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL FLEXLOGIC DESIGN USING ENGINEER CHAPTER 4 INTERFACES 4 ...
Страница 692: ...6 36 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL PRODUCT INFORMATION CHAPTER 6 ACTUAL VALUES 6 ...
Страница 708: ...7 16 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL TARGETS MENU CHAPTER 7 COMMANDS AND TARGETS 7 ...
Страница 742: ...9 6 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL TESTING CHAPTER 9 COMMISSIONING 9 ...
Страница 804: ...10 62 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL FAULT LOCATOR CHAPTER 10 THEORY OF OPERATION 10 ...
Страница 872: ...C 6 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL COMMAND LINE INTERFACE APPENDIX C COMMAND LINE INTERFACE C ...
Страница 878: ...D 6 L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL REVISION HISTORY APPENDIX D MISCELLANEOUS D ...
Страница 882: ...iv L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL ABBREVIATIONS ...
Страница 900: ...xviii L90 LINE CURRENT DIFFERENTIAL SYSTEM INSTRUCTION MANUAL INDEX ...