B-36
B90 Low Impedance Bus Differential System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
AC98
IEC 61850 logical node PDISx name prefix (10 items)
0 to 65534
---
1
F206
(none)
ACB6
IEC 61850 logical node RBRFx name prefix (24 items)
0 to 65534
---
1
F206
(none)
ACFE
IEC 61850 logical node RPSBx name prefix
0 to 65534
---
1
F206
(none)
AD01
IEC 61850 logical node RRECx name prefix (6 items)
0 to 65534
---
1
F206
(none)
AD13
IEC 61850 logical node MMXUx name prefix (6 items)
0 to 65534
---
1
F206
(none)
AD25
IEC 61850 logical node GGIOx name prefix (5 items)
0 to 65534
---
1
F206
(none)
AD34
IEC 61850 logical node RFLOx name prefix (5 items)
0 to 65534
---
1
F206
(none)
AD43
IEC 61850 logical node XCBRx name prefix (6 items)
0 to 65534
---
1
F206
(none)
AD55
IEC 61850 logical node PTRCx name prefix (6 items)
0 to 65534
---
1
F206
(none)
AD67
IEC 61850 logical node PDIFx name prefix (6 items)
0 to 65534
---
1
F206
(none)
AD73
IEC 61850 logical node MMXNx name prefix (6 items)
0 to 65534
---
1
F206
(none)
ADE2
IEC 61850 logical node CSWIx name prefix (6 items)
0 to 65534
---
1
F206
(none)
AE3C
IEC 61850 logical node XSWIx name prefix (6 items)
0 to 65534
---
1
F206
(none)
IEC 61850 GGIO4 general analog configuration settings (read/write)
AF00
Number of analog points in GGIO4
4 to 32
---
4
F001
4
AF01
GOOSE analog scan period
100 to 5000
---
10
F001
1000
IEC 61850 GGIO4 analog input points configuration settings (read/write)
AF10
IEC 61850 GGIO4 analog input 1 value
---
---
---
F600
0
AF11
IEC 61850 GGIO4 analog input 1 deadband
0.001 to 100
%
0.001
F003
100000
AF13
IEC 61850 GGIO4 analog input 1 minimum
–1000000000000 to
1000000000000
---
0.001
F060
0
AF15
IEC 61850 GGIO4 analog input 1 maximum
–1000000000000 to
1000000000000
---
0.001
F060
1000000
AF17
...Repeated for IEC 61850 GGIO4 analog input 2
AF1E
...Repeated for IEC 61850 GGIO4 analog input 3
AF25
...Repeated for IEC 61850 GGIO4 analog input 4
AF2C
...Repeated for IEC 61850 GGIO4 analog input 5
AF33
...Repeated for IEC 61850 GGIO4 analog input 6
AF3A
...Repeated for IEC 61850 GGIO4 analog input 7
AF41
...Repeated for IEC 61850 GGIO4 analog input 8
AF48
...Repeated for IEC 61850 GGIO4 analog input 9
AF4F
...Repeated for IEC 61850 GGIO4 analog input 10
AF56
...Repeated for IEC 61850 GGIO4 analog input 11
AF5D
...Repeated for IEC 61850 GGIO4 analog input 12
AF64
...Repeated for IEC 61850 GGIO4 analog input 13
AF6B
...Repeated for IEC 61850 GGIO4 analog input 14
AF72
...Repeated for IEC 61850 GGIO4 analog input 15
AF79
...Repeated for IEC 61850 GGIO4 analog input 16
AF80
...Repeated for IEC 61850 GGIO4 analog input 17
AF87
...Repeated for IEC 61850 GGIO4 analog input 18
AF8E
...Repeated for IEC 61850 GGIO4 analog input 19
AF95
...Repeated for IEC 61850 GGIO4 analog input 20
AF9C
...Repeated for IEC 61850 GGIO4 analog input 21
AFA3
...Repeated for IEC 61850 GGIO4 analog input 22
AFAA
...Repeated for IEC 61850 GGIO4 analog input 23
AFB1
...Repeated for IEC 61850 GGIO4 analog input 24
AFB8
...Repeated for IEC 61850 GGIO4 analog input 25
AFBF
...Repeated for IEC 61850 GGIO4 analog input 26
AFC6
...Repeated for IEC 61850 GGIO4 analog input 27
AFCD
...Repeated for IEC 61850 GGIO4 analog input 28
AFD4
...Repeated for IEC 61850 GGIO4 analog input 29
AFDB
...Repeated for IEC 61850 GGIO4 analog input 30
AFE2
...Repeated for IEC 61850 GGIO4 analog input 31
AFE9
...Repeated for IEC 61850 GGIO4 analog input 32
Table B–9: MODBUS MEMORY MAP (Sheet 29 of 48)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание B90 UR Series
Страница 28: ...1 20 B90 Low Impedance Bus Differential System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 114: ...4 28 B90 Low Impedance Bus Differential System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 272: ...6 14 B90 Low Impedance Bus Differential System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 316: ...A 4 B90 Low Impedance Bus Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 406: ...B 90 B90 Low Impedance Bus Differential System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 436: ...C 30 B90 Low Impedance Bus Differential System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Страница 446: ...D 10 B90 Low Impedance Bus Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...