GE Multilin
B90 Low Impedance Bus Differential System
B-39
APPENDIX B
B.4 MEMORY MAPPING
B
B5CB
Configurable GOOSE dataset items for transmission
(64 items)
0 to 542
---
1
F616
0 (None)
B60B
...Repeated for Module 2
B676
...Repeated for Module 3
B6E1
...Repeated for Module 4
B74C
...Repeated for Module 5
B7B7
...Repeated for Module 6
B822
...Repeated for Module 7
B88D
...Repeated for Module 8
IEC 61850 Configurable GOOSE Reception (Read/Write Setting) (16 modules)
B900
Configurable GOOSE dataset items for reception
(32 items)
0 to 197
---
1
F233
0 (None)
B920
...Repeated for Module 2
B940
...Repeated for Module 3
B960
...Repeated for Module 4
B980
...Repeated for Module 5
B9A0
...Repeated for Module 6
B9C0
...Repeated for Module 7
B9E0
...Repeated for Module 8
BA00
...Repeated for Module 9
BA20
...Repeated for Module 10
BA40
...Repeated for Module 11
BA60
...Repeated for Module 12
BA80
...Repeated for Module 13
BAA0
...Repeated for Module 14
BAC0
...Repeated for Module 15
BAE0
...Repeated for Module 16
Contact Inputs (Read/Write Setting) (96 modules)
BB00
Contact Input 1 Name
---
---
---
F205
“Cont Ip 1“
BB06
Contact Input 1 Events
0 to 1
---
1
F102
0 (Disabled)
BB07
Contact Input 1 Debounce Time
0 to 16
ms
0.5
F001
20
BB08
...Repeated for Contact Input 2
BB10
...Repeated for Contact Input 3
BB18
...Repeated for Contact Input 4
BB20
...Repeated for Contact Input 5
BB28
...Repeated for Contact Input 6
BB30
...Repeated for Contact Input 7
BB38
...Repeated for Contact Input 8
BB40
...Repeated for Contact Input 9
BB48
...Repeated for Contact Input 10
BB50
...Repeated for Contact Input 11
BB58
...Repeated for Contact Input 12
BB60
...Repeated for Contact Input 13
BB68
...Repeated for Contact Input 14
BB70
...Repeated for Contact Input 15
BB78
...Repeated for Contact Input 16
BB80
...Repeated for Contact Input 17
BB88
...Repeated for Contact Input 18
BB90
...Repeated for Contact Input 19
BB98
...Repeated for Contact Input 20
BBA0
...Repeated for Contact Input 21
BBA8
...Repeated for Contact Input 22
BBB0
...Repeated for Contact Input 23
BBB8
...Repeated for Contact Input 24
BBC0
...Repeated for Contact Input 25
Table B–9: MODBUS MEMORY MAP (Sheet 32 of 48)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание B90 UR Series
Страница 28: ...1 20 B90 Low Impedance Bus Differential System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 114: ...4 28 B90 Low Impedance Bus Differential System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 272: ...6 14 B90 Low Impedance Bus Differential System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 316: ...A 4 B90 Low Impedance Bus Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 406: ...B 90 B90 Low Impedance Bus Differential System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 436: ...C 30 B90 Low Impedance Bus Differential System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Страница 446: ...D 10 B90 Low Impedance Bus Differential System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...