Appendix A OBP Environment Variables
(6)
local-mac-address?
If the value is true, the network driver uses its own MAC address. If the value is false,
a MAC address of the system is applied. For a PRIMEPOWER850, all system board
on-board LAN ports have the same MAC address of the system even if the setting
value is true.
The default value is false.
(7)
diag-level
max:
Operate power-on diagnosis in maximum range. This level of diagnostics
requires more time during start-up, and should not be used in normal
operation.
min:
Operate normal power-on diagnosis (default setting).
off:
Do not perform power-on diagnosis. If diag-level is set to off, a system
component failure could result in loss of data.