U41261-J-Z816-4-76
129
7.3 Error Messages Displayed on the Operator Panel
Table 7.2 Error messages displayed on the operator panel (1/3)
No.
Message
Explanation
Remarks
1
OBP:ERROR
OBP detected an error.
-
Check errorlogs
This message is displayed
when the Cursor switch is
pressed.
2
OBP:ERROR
A RED state trap occurred.
-
RED state trap
This message is displayed
when the Cursor switch is
pressed
3
POST:ERxxxxxxxx
An error occurred in the system board or in a
unit on the system board.
-
SB#L
This message is displayed
when the Cursor switch is
pressed.
4
POST:ERxxxxxxxx
An error occurred in an SCFA or in a unit on
the SCFA.
-
SCFA#L
This message is displayed
when the Cursor switch is
pressed.
5
POST:ERxxxxxxxx
An error occurred in the CPU.
-
SB#L CPU#NN
This message is displayed
when the Cursor switch is
pressed.NN: Unit number
6
POST:ERxxxxxxxx
A memory error occurred.
-
SB#L DIMM#NN
This message is displayed
when the Cursor switch is
pressed.NN: Unit number
7
POST:ERxxxxxxxx
A memory configuration error occurred.
-
SB#L DIMM Conf
This message is displayed
when the Cursor switch is
pressed.
8
POST:ERxxxxxxxx
An error occurred in the PCI adapter on
SCFA.
-
SCFA#L PCI#NN
This message is displayed
when the Cursor switch is
pressed.
NN: Unit number
9
POST:ERxxxxxxxx
An error occurred in the PCI adapter on
PCIBOX.
-
PCIBOX#L PCI#NN
This message is displayed
when the Cursor switch is
pressed.
NN: Unit number
10 INPUT#L FAIL
An input power error occurred.
-
#L:
Location number of the unit where the error occurred
Содержание PRIMEPOWER650
Страница 1: ...Edition September 2004 PRIMEPOWER850 650 ...
Страница 22: ......
Страница 30: ......
Страница 81: ...U41261 J Z816 4 76 51 2 5 Configuring for the Fast Memory Mode ...
Страница 82: ......
Страница 154: ......
Страница 162: ......
Страница 172: ......
Страница 180: ......
Страница 192: ......
Страница 194: ......