U41261-J-Z816-4-76
135
A.2 Other OBP Environment Variables
• Check command
l
When set value is zero, the following line appears:
• Setting command
l
To set waiting time of 300 seconds, enter the following command:
(2)
diag-retry
If an error is detected in accessing to the target disk during the boot-up process of the
main unit, attempts to shut down and reboot the target disk unit through a retry
process may possibly run the target disk unit.
This situation could occur if the diag-retry variable is set to on and the system is
configured to enable automatic shutdown and then reboot. The variable default value
is off.
(3)
boot-device
Sets boot-up target disk. This value is set by the install program during the OS
installation. This setting is enabled when the value of diag-switch? in the OBP
environment is set to false.
(4)
boot-file
Sets a boot file. This setting is enabled when the value of diag-switch? in the OBP
environment is set to false.
(5)
scsi-initiator-id
Sets the host side address of the SCSI bus. Range is from 0 to 7. The default value is
7.
ok
printenv boot-wait-time
boot-wait-time=0
ok
setenv boot-wait-time 300