5-1
5. Function Selection
·
When the retry function is selected, the inverter may restart automatically after tripping.
(Design the machine to ensure personal safety in the event of restart)
Accident may result.
·
When the torque limiting function is selected, operating conditions may differ from preset conditions
(acceleration/deceleration time or speed). In this case, personal safety must be assured.
Accident may result.
·
If AUTO RESTART is selected in the restart mode after momentary power failure (function code F14), the
inverter restarts automatically starting the motor rotation when the power is re-supplied.
Accident may result.
·
When auto tuning (function code H01) is started, the motor, machine or equipment starts and stops
repeatedly. Ensure safety before performing auto tuning.
Accident may result.
·
If the user set the function codes wrongly or without completely understanding this user’s manual, the
motor may rotate with a torque or at a speed not permitted for the machine.
Accident or injury may result.
·
During pre-excitation, the speed adjuster does not function and the motor may be rotated by load
disturbance. When using pre-excitation, therefore, also use the machine brake.
Injury may result.
·
If improper data is set at the function code related with speed adjuster as in the case of setting high gain
abruptly, the motor may hunt.
Injury may result.
Содержание 5000VG7S Series
Страница 7: ...0 6 Warning Label Position for Inside the Inverter...
Страница 23: ...2 5 Basic Wiring Diagram Figure 2 3 1 Basic Wiring Diagram...
Страница 36: ...2 18 l Control circuit terminals Control circuit terminals Screw size M3...
Страница 94: ...9 4 FS5941 40 47 Figure 9 1 FS5941 60 52 FS5941 86 52 Figure 9 2...
Страница 96: ...9 6 RF3280 F11 RF3400 F11 Figure 9 5 RF3880 F11 Figure 9 6 6 6 Figure 9 7 F200160...