5-12
Function codes “S” and “M” are codes to access the inverter
through links (RS485, T-Link, SX communication, field bus, etc).
You cannot use them with the KEYPAD panel.
Though you can access the codes “F” to “U” codes through these
links, these links are specifically designed to access the code “S”
for operation and control and the “M” for data monitoring.
S: Serial Communication Functions
Communication
address
Fcode
485
number Link number
Function name
Data setting range
S01
701h
1( 1 h) Frequency / speed reference (Setting 1)
-24000 to 24000 r/min
: (data)*Nmax/20000
S02
702h
2( 2 h) Torque reference
0.01% / 1d
S03
703h
3( 3 h) Torque current reference
0.01% / 1d
S04
704h
4( 4 h) Magnetic-flux reference
0.01% / 1d
S05
705h
5( 5 h) Orientation position reference
0000 to FFFF
S06
706h
6( 6 h) Operation method 1
0000 to FFFF
S07
707h
7( 7 h) Universal Do
0000 to FFFF
S08
708h
8( 8 h) Acceleration time
0.0 to 3600.0 s
S09
709h
9( 9 h) Deceleration time
0.0 to 3600.0 s
S10
70Ah
10( A h) Torque limiter level 1
0.01% / 1d
S11
70Bh
11( B h) Torque limiter level 2
0.01% / 1d
S12
70Ch
12( C h) Operation method 2
0000 to FFFF
M: Monitoring Functions
Communication
address
Fcode
485
number
Link number
Function name
Data setting range
M01
801h 15( F h) Speed setting 4 (ASR input)
-24000 to 24000 r/min
: (data)*Nmax/20000
M02
802h
16( 10 h) Torque reference
0.01% / 1d
M03
803h
17( 11 h) Toque current reference
0.01% / 1d
M04
804h
18( 12 h) Magnetic-flux reference
0.01% / 1d
M05
805h
19( 13 h) Output frequency reference
0.1Hz / 1d
M06
806h
20( 14 h) Detected speed value
-24000 to 24000 r/min
: (data)*Nmax/20000
M07
807h
21( 15 h) Calculated torque value
0.01% / 1d
M08
808h
22( 16 h) Calculated torque current value
0.01% / 1d
M09
809h
23( 17 h) Output frequency
0.1Hz / 1d
M10
80Ah
24( 18 h) Motor output
0.1kW / 1d
M11
80Bh
25( 19 h) Output current rms value
0.1A / 1d
M12
80Ch
26( 1A h) Output voltage rms value
0.1V / 1d
M13
80Dh
27( 1B h) Operation method (final command)
0000 to FFFF
M14
80Eh
28( 1C h) Operation status
0000 to FFFF
M15
80Fh
29( 1D h) Output terminals Y1 - Y18
0000 to FFFF
M16
810h
30( 1E h) Latest alarm data
0 to 48
M17
811h
31( 1F h) Last alarm data
0 to 48
M18
812h
32( 20 h) Second last alarm data
0 to 48
M19
813h
33( 21 h) Third last alarm data
0 to 48
M20
814h
34( 22 h) Accumulated operation time
0 to 65535 h
M21
815h
35( 23 h) DC link circuit voltage
1V / 1d
M22
816h
36( 24 h) Motor temperature
1 °C
/ 1d
M23
817h
37( 25 h) Type code
0000 to FFFF
M24
818h
38( 26 h) Capacity code
0 to 29
M25
819h
39( 27 h) Inverter ROM (main control) version
0000 to FFFF
M26
81Ah
40( 28 h) Communication error code
0 to 65535
M27
81Bh
41( 29 h) Speed setting on alarm
-24000 to 24000 r/min
: (data)*Nmax/20000
M28
81Ch
42( 2A h) Torque reterence on alarm
0.01% / 1d
M29
81Dh
43( 2B h) Torque current reference on alarm
0.01% / 1d
M30
81Eh
44( 2C h) Magnetic-flux reference on alarm
0.01% / 1d
M31
81Fh
45( 2D h) Output frequency reference on alarm
0.1Hz / 1d
M32
820h
46( 2E h) Detected speed on alarm
-24000 to 24000 r/min
: (data)*Nmax/20000
M33
821h
47( 2F h) Calculated torque on alarm
0.01% / 1d
M34
822h
48( 30 h) Calculated torque current on alarm
0.01% / 1d
M35
823h
49( 31 h) Output frequency on alarm
0.1Hz / 1d
M36
824h
50( 32 h) Motor output on alarm
0.1kW / 1d
M37
825h
51( 33 h) Output current rms value on alarm
0.1A / 1d
M38
826h
52( 34 h) Output voltage rms value on alarm
0.1V / 1d
M39
827h
53( 35 h) Operation method on alarm
0000 to FFFF
M40
828h
54( 36 h) Operation status on alarm
0000 to FFFF
M41
829h
55( 37 h) Output terminal on alarm
0000 to FFFF
M42
82Ah
56( 38 h) Accumulated operation time on alarm
0 to 65535 h
M43
82Bh
57( 39 h) DC link circuit voltage on alarm
0.1V / 1d
M44
82Ch
58( 3A h) Inverter intemal temperature on alarm
1 °C
/ 1d
M45
82Dh
59( 3B h) Heat sink temperature on alarm
1 °C
/ 1d
M46
82Eh
60( 3C h) Main circuit capacitor capacity
0 to 100 %
M47
82Fh
61( 3D h) PC board capacitor life on alarm
0 to 65535 h
Communication
address
Fcode
485
number
Link number
Function name
Data setting range
M48
830h
62( 3E h) Cooling fan life
0 to 65535 h
M49
831h
63( 3F h) Speed setting 1
(before multistep speed command)
-24000 to 24000 r/min
: (data)*Nmax/20000
M50
832h
64( 40 h) Speed setting 2
(before calculation of accel/decel.)
-24000 to 24000 r/min
: (data)*Nmax/20000
M51
833h
65( 41 h) Speed setting 3 (after speed limit)
-24000 to 24000 r/min
: (data)*Nmax/20000
M52
834h
66( 42 h) Control output 1
0000 to FFFF
M53
835h
67( 43 h) Control output 2
0000 to FFFF
M54
836h
68( 44 h) Control output 3
0000 to FFFF
M55
837h
69( 45 h) Option monitor 1
0000 to FFFF
M56
838h
70( 46 h) Option monitor 2
0000 to FFFF
M57
839h
71( 47 h) Option monitor 3
0 to 65535
M58
83Ah
72( 48 h) Option monitor 4
0 to 65535
M59
83Bh
73( 49 h) Option monitor 5
-32768 to 32767
M60
83Ch
74( 4A h) Option monitor 6
-32768 to 32767
You can change the setting of a function indicated by during operation.
You should stop operation to change the setting of other functions.
Underline indicates a factory setting.
Items without underline have different factory settings according to capacity.
Содержание 5000VG7S Series
Страница 7: ...0 6 Warning Label Position for Inside the Inverter...
Страница 23: ...2 5 Basic Wiring Diagram Figure 2 3 1 Basic Wiring Diagram...
Страница 36: ...2 18 l Control circuit terminals Control circuit terminals Screw size M3...
Страница 94: ...9 4 FS5941 40 47 Figure 9 1 FS5941 60 52 FS5941 86 52 Figure 9 2...
Страница 96: ...9 6 RF3280 F11 RF3400 F11 Figure 9 5 RF3880 F11 Figure 9 6 6 6 Figure 9 7 F200160...