7-6
4) Motor presents hunting
5) Motor is unstable on acceleration/deceleration
Motor is unstable
on acceleration/
deceleration.
Readjust constants of speed control system
(code F61 to F66, C30 to C34, C40 to C45,
C50 to C55, and C60 to C65).
You can increase ASR (P constant) of function code
to reduce overshoot/undershoot in general.
Motor presents hunting.
Adjust constants
of speed
control system.
NO
Motor speed fluctuates when load changes in large amount.
You can quicken response of speed control system
to reduce speed fluctuation.
Readjust constants of speed control system.
If you still cannot operate correctly, contact FUJI.
Inverter fault is
suspected.
Contact FUJI.
Change data of
function code P02
to match.
Execute motor
parameter tuning
(function code H01).
NO
Take measure to
keep speed
reference constant.
NO
YES
YES
NO
YES
YES
NO
YES
Do motor parameters
(function code P and
A) match companion
motor?
Did you adjust
constants of speed
control system
(code F61 to F66, C30
to C34, C40 to C45,
C50 to C55, and C60
to C65)?
Does speed reference
fluctuates?
Does load fluctuates?
Is motor dedicated to
VG7?
Содержание 5000VG7S Series
Страница 7: ...0 6 Warning Label Position for Inside the Inverter...
Страница 23: ...2 5 Basic Wiring Diagram Figure 2 3 1 Basic Wiring Diagram...
Страница 36: ...2 18 l Control circuit terminals Control circuit terminals Screw size M3...
Страница 94: ...9 4 FS5941 40 47 Figure 9 1 FS5941 60 52 FS5941 86 52 Figure 9 2...
Страница 96: ...9 6 RF3280 F11 RF3400 F11 Figure 9 5 RF3880 F11 Figure 9 6 6 6 Figure 9 7 F200160...