7-24
(16) CPU error and A/D converter error
(17) Output wiring error
YES
Treat defective part.
A/D converter error
Er8
CPU error
Er3
Inverter fault is
suspected.
Contact FUJI.
NO
Is there short circuit on
PCB?
Is dust attached on
PCB?
YES
NO
Connect following
wiring diagram.
Review data and execute
motor parameter tuning
(function code H01) again.
Output wiring error
Er7
Inverter fault is
suspected.
Contact FUJI.
YES
NO
Is inverter output
wiring (U, V, W)
disconnected?
Do motor parameters
(function code P and
A) match companion
motor?