1-3
1-4 Transportation
Always hold the body during transportation.
Do not hold the cover or any other part. Doing so may break or fall the product.
When using a hoist or crane to transport a product with lifting holes, hang hooks and ropes to the holes.
1-5 Storage
Store the product under the conditions specified on Table 1-5-1.
Table 1-5-1 Storage Conditions
Item
Requirement
Ambient temperature
-
10 to +50°C
Storage temperature
See Note 1
-
25 to +65°C
Relative humidity
5% to 95%
See Note 2
No condensation or freezing should occur
due to sudden temperature changes.
Atmosphere
The product should not be exposed to dust, direct sunlight, corrosive or
combustible gas, oil mist, vapor, waterdrops, vibration, or air containing
much salt.
Note 1:
The storage temperature applies to the temporary storage during transportation, for example.
Note 2:
Do not store the product in a place where the temperature significantly changes as this may cause
condensation or freezing even if the humidity requirement is satisfied.
(1) Do not place the product directly on the floor.
(2) Pack the product with a plastic sheet or such if stored under undesirable conditions.
(3) Seal in a desiccative such as silica gel when packing the product if it may be affected by moisture.
The requirements to be satisfied when storing the product for an extended period after purchased greatly
depend on the environment. General requirements are listed below.
(1) Satisfy the requirements for temporary storage.
If the storage period exceeds three months, the ambient temperature should be kept below 30 °C to protect
the dead electrolytic capacitor from deterioration.
(2) Carefully pack the product to prevent the intrusion of moisture, etc. Seal in a desiccant to keep the relative
humidity inside the pack below 70%, as a guide.
(3) The product will be often exposed to moisture or dust if left mounted on a unit or console, especially in a
building under construction. In such a case, remove the product and relocate in a well-conditioned place.
The electrolytic capacitor will be deteriorated if left dead for an extended period. Do not leave it dead for a
period exceeding a year.
Temporary Storage
Extended Storage
Содержание 5000VG7S Series
Страница 7: ...0 6 Warning Label Position for Inside the Inverter...
Страница 23: ...2 5 Basic Wiring Diagram Figure 2 3 1 Basic Wiring Diagram...
Страница 36: ...2 18 l Control circuit terminals Control circuit terminals Screw size M3...
Страница 94: ...9 4 FS5941 40 47 Figure 9 1 FS5941 60 52 FS5941 86 52 Figure 9 2...
Страница 96: ...9 6 RF3280 F11 RF3400 F11 Figure 9 5 RF3880 F11 Figure 9 6 6 6 Figure 9 7 F200160...