7-4
2) Motor runs but does not change speed
Motor runs but does
not change speed.
Rewrite data according
to specification.
NO
UP/DOWN
setting
Multistep
speed setting
NO
YES
YES
YES
KEYPAD
panel
YES
Analog input
NO
Is speed limiter
activated
(code F76 to F78)?
Which means do you
use to set speed?
Does speed signal
(0 to
±
10V) change?
Use and
to adjust speed.
∨
∧
Can you press
or
to change speed?
∨
Is the maximum speed
set to too low
(code F03, A06, or
A40)?
∧
NO
NO
Rewrite data according
to specification.
NO
Inverter fault is
suspected.
Contact FUJI.
NO
Fault in speed
reference setting
device or signal converter
is suspected.
Adjust wiring.
Rewrite data according
to specification.
YES
YES
YES
YES
YES
NO
Is wiring to control
terminal 13, 12, and 11
connected correctly?
Is wiring to control
terminal X connected
correctly?
Are correct data for
E01 to E14 specified?
Are correct data for
multistep speed setting
(code C05 to C21)
specified?
Are acceleration/
deceleration times
are too long
(code F07, F08, C35,
C36, C46, C47, C56,
C57, C66 and C67)?
NO
Содержание 5000VG7S Series
Страница 7: ...0 6 Warning Label Position for Inside the Inverter...
Страница 23: ...2 5 Basic Wiring Diagram Figure 2 3 1 Basic Wiring Diagram...
Страница 36: ...2 18 l Control circuit terminals Control circuit terminals Screw size M3...
Страница 94: ...9 4 FS5941 40 47 Figure 9 1 FS5941 60 52 FS5941 86 52 Figure 9 2...
Страница 96: ...9 6 RF3280 F11 RF3400 F11 Figure 9 5 RF3880 F11 Figure 9 6 6 6 Figure 9 7 F200160...