Introduction
and
Specifications
Detailed Specifications
1
1-15
AC Current (Sine Wave) (cont.)
Absolute Uncertainty,
tcal
±
5
°
C
±
(% of
μ
A)
Range Frequency
90 days
1 year
Max Distortion &
Noise 10 Hz to
100 kHz BW
±
(% of floor)
Max
Inductive
Load
μ
H
LCOMP On
10 to 100 Hz
0.2 + 0.2
0.25 + 0.2
0.1 + 1.0
29.00 to
329.99
μ
A
100 Hz to 1 kHz
0.5 + 0.5
0.6 + 0.5
0.05 + 1.0
10 to 100 Hz
0.2 + 0.3
0.25 + 0.3
0.15 + 1.5
0.33 to
3.29999 mA
100 Hz to 1 kHz
0.5 + 0.8
0.6 + 0.8
0.06 + 1.5
10 to 100 Hz
0.07 + 4
0.08 + 4
0.15 + 5
3.3 to
32.9999 mA
100 Hz to 1 kHz
0.18 + 10
0.2 + 10
0.05 + 5
10 to 100 Hz
0.07 + 40
0.08 + 40
0.15 + 50
33 to
329.999 mA
100 Hz to 1 kHz
0.18 + 100
0.2 + 100
0.05 + 50
10 to 100 Hz
0.1 + 200
0.12 + 200
0.2 + 500
0.33 to
2.99999 A
100 to 440 Hz
0.25 + 1000
0.3 + 1000
0.25 + 500
400
10 to 100 Hz
0.1 + 2000
[2]
0.12 + 2000
[2]
0.1 + 0
3 to 20.5 A
[1]
100 Hz to 1 kHz
0.8 + 5000
[3]
1.0 + 5000
[3]
0.5 + 0
400
[4]
[1]
Duty Cycle: Currents <11 A may be provided continuously. For currents >11 A, see Figure B. The current may be provided 60-
T-I minutes any 60 minute period where T is the temperature in
°
C (room temperature is about 23
°
C) and I is the output
current in Amps. For example, 17 A, at 23
°
C could be provided for 60-17-23 = 20 minutes each hour. When the 5522A is
outputting currents between 5 and 11 amps for long periods, the internal self-heating reduces the duty cycle. Under those
conditions, the allowable "on" time indicated by the formula and Figure B is achieved only after the 5522A is outputting currents
<5 A for the "off" period first.
[2]
For currents >11 A, Floor specification is 4000
μ
A within 30 seconds of selecting operate. For operating times >30 seconds,
the floor specification is 2000
μ
A.
[3]
For currents >11 A, Floor specification is 1000
μ
A within 30 seconds of selecting operate. For operating times >30 seconds,
the floor specification is 5000
μ
A.
[4]
Subject to compliance voltages limits.
Range
Resolution
μ
A
Max Compliance Voltage V rms
[1]
0.029 to 0.32999 mA
0.01
7
0.33 to 3.29999 mA
0.01
7
3.3 to 32.9999 mA
0.1
5
33 to 329.999 mA
1
5
0.33 to 2.99999 A
10
4
3 to 20.5 A
100
3
[1]
Subject to specification adder for compliance voltages greater than 1 V rms.
Содержание 522A/6
Страница 4: ......
Страница 14: ...5522A Operators Manual x...
Страница 18: ...5522A Operators Manual xiv...
Страница 22: ...5522A Operators Manual 1 2...
Страница 46: ...5522A Operators Manual 1 26...
Страница 48: ...5522A Operators Manual 2 2...
Страница 54: ...5522A Operators Manual 2 8...
Страница 56: ...5522A Operators Manual 3 2...
Страница 189: ...6 1 Chapter 6 Remote Commands Title Page Introduction 6 3 Command Summary by Function 6 3 Commands 6 10...
Страница 190: ...5522A Operators Manual 6 2...
Страница 240: ...5522A Operators Manual 7 2...
Страница 260: ...5522A Operators Manual 8 2...
Страница 314: ...5522A Operators Manual 9 52...
Страница 370: ...5522A Operators Manual 10 56...
Страница 413: ...B 1 Appendix B ASCII and IEEE 488 Bus Codes...
Страница 414: ...5522A Operators Manual B 2...
Страница 416: ...5522A Operators Manual B 4...