Installation
CB-640x Installation and User Guide Revision 100
February 2021
11
This document does not contain any export-controlled information.
•
Use best security practices to design and maintain secured camera access, communications
infrastructure, tamper-proof outdoor boxes, etc.
•
All electrical work must be performed in accordance with local regulatory requirements.
3.3 Outdoor Mounting Recommendations
Following are additional considerations for outdoor installation:
•
For outside wiring installation, always use weatherproof equipment, such as boxes, receptacles,
connectors, etc.
•
For electrical wiring, use the properly rated sheathed cables for conditions to which the cable will be
exposed (for example, moisture, heat, UV, physical requirements, etc.).
•
Plan ahead to determine where to install infrastructure weatherproof equipment. Whenever possible,
ground components to an outdoor ground.
3.4 Hardware Description
Figure 7: Hardware
Component
Description
1 RJ-45 connector
See
2 Power connector
3 Digital I/O connectors
Caution
To avoid damage from overheating or unit failure, assure that there is sufficient temperature
regulation to support the unit’s requirements (cooling/heating). Operating temperature should be kept
in the range -40°C to 60°C (-40°F to 140°F), with no more than 95% non-condensing humidity.
Attention
Afin d'éviter tout dommage dû à une surchauffe ou toute panne de l'unité, assurez-vous que la
régulation de température est suffisante pour répondre aux exigences de l'unité
(refroidissement/chauffage). La température de fonctionnement doit être maintenue dans la plage
(-40° à 60°C/-40° à 140°F), sans condensation d'humidité supérieur à 95%.