Configuration
CB-640x Installation and User Guide Revision 100
February 2021
70
This document does not contain any export-controlled information.
Caution
Only upgrade to firmware developed for the specific Quasar CB-640x camera you are
upgrading.
3. Click
Upgrade
.
The camera uploads and installs the firmware, which takes about three minutes. After installing firmware,
the camera reboots.
Reset factory default and reboot
Click
Full Reset
to return the camera its original factory configuration, including the camera’s original
networking settings.
Caution
Clicking
Full Reset
causes the camera to lose all network settings.
Attention
En cliquant sur Réinitialisation complète, la caméra perd tous les paramètres réseau.
Click
Partial Reset
to return the camera to its factory configuration, except for the camera’s network
settings (IP address, subnet mask, and default gateway), video format, and image rotation settings.
Click
Reboot
to restart the camera without affecting the configured settings.
To import settings using a previously exported settings file:
1. Under
Import Setting
, click
Find file
.
2. On your computer or network, browse to and select the settings file.
3. Click
Import
to upload the file.
To export the camera’s current settings:
1. Under
Export Setting
, click
Export
.
In Internet Explorer, an information bar appears.
2. In Internet Explorer, click
Save
. For other browsers, save the file.
Support package
: To download camera log files for FLIR Support personnel, click
Download
.