Page 234
Manual
ResistTel IP2 / IP152
ExResistTel IP2 / IP154
Before configuring the second or following registrations, the corresponding
registration should be made possible through ‘enable’. By deactivating ‚enable’, the
complete registration can be cancelled, whereby the loss of the parameters is ruled
out.
Note
If a device is updated from an older software version and is configured to one of
the protocols SIP, TSIP or SIPS or the protocol is changed from H323 to SIP, TSIP
or SIPS and neither proxy nor alternate proxy are configured, then the at
gatekeeper address configured IP address will be used for the registration at a SIP
server.
If the gatekeeper or alternate gatekeeper address will be sent via DHCP to the
device, then this address will be used independent of the configuration of the
gatekeeper in the device and independent of the selected protocol.
If a gatekeeper address is defined as domain name via DHCP, then this is not
working with the protocol H323 and not working with devices with older software
versions.
Содержание ExResistTel IP2/IP154
Страница 1: ...Explosion proof and weatherproof VoIP telephones Operating instructions FHF BA 9710 6 03 13 V9 4 4 ...
Страница 43: ...Manual ResistTel IP2 IP152 Page 43 ExResistTel IP2 IP154 Figure 9 Set View ...
Страница 44: ...Page 44 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 Figure 10 Inside View of Telephone upper Part ...
Страница 375: ...Manual ResistTel IP2 IP152 Page 375 ExResistTel IP2 IP154 9 Connect the device with the power supply again ...
Страница 385: ...Manual ResistTel IP2 IP152 Page 385 ExResistTel IP2 IP154 5 3 2 EC Type Examination Certificate ExResistTel IP2 IP154 ...
Страница 386: ...Page 386 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 ...
Страница 387: ...Manual ResistTel IP2 IP152 Page 387 ExResistTel IP2 IP154 ...
Страница 389: ...Manual ResistTel IP2 IP152 Page 389 ExResistTel IP2 IP154 5 3 4 Declaration of Conformity ExResistTel IP2 IP154 ...
Страница 390: ...Page 390 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 ...