Page 32
Manual
ResistTel IP2 / IP152
ExResistTel IP2 / IP154
2.3.2.3.3
LAN Interface 10/100 BASE-TX according to IEEE
802.3 (not intrinsically safe)
Terminal no.: 8, 9, 10, 13
U
n
= ±2.5 V (10 BASE-TX)
respectively
U
n
= ±1 V (100 BASE-TX)
U
m
= ±7 V
U
m
= DC 57 V
For the LAN connection it is only allowed to use cables of the type CAT5e or higher.
To observe the EMC rules with netting shielded cables have to be used.
2.3.2.3.4
Potential-free Relay Contacts (not intrinsically safe)
Terminal no.: 18, 20 respectively no.: 21, 23
•
U
max
= AC 250 V
I
max
= 5 A
P
max
= 100 VA
For this connection cables with a transversal section of 1.5 mm² to 4 mm² are
allowed to be used only.
•
U
max
= DC 230 V
I
max
= 0.5 A
P
max
= 100 W
For this connection cables with a transversal section of 0.75 mm² to 4 mm²
are allowed to be used only.
Содержание ExResistTel IP2/IP154
Страница 1: ...Explosion proof and weatherproof VoIP telephones Operating instructions FHF BA 9710 6 03 13 V9 4 4 ...
Страница 43: ...Manual ResistTel IP2 IP152 Page 43 ExResistTel IP2 IP154 Figure 9 Set View ...
Страница 44: ...Page 44 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 Figure 10 Inside View of Telephone upper Part ...
Страница 375: ...Manual ResistTel IP2 IP152 Page 375 ExResistTel IP2 IP154 9 Connect the device with the power supply again ...
Страница 385: ...Manual ResistTel IP2 IP152 Page 385 ExResistTel IP2 IP154 5 3 2 EC Type Examination Certificate ExResistTel IP2 IP154 ...
Страница 386: ...Page 386 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 ...
Страница 387: ...Manual ResistTel IP2 IP152 Page 387 ExResistTel IP2 IP154 ...
Страница 389: ...Manual ResistTel IP2 IP152 Page 389 ExResistTel IP2 IP154 5 3 4 Declaration of Conformity ExResistTel IP2 IP154 ...
Страница 390: ...Page 390 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 ...