Manual ResistTel IP2 / IP152
Page 31
ExResistTel IP2 / IP154
2.3.2.3
Electrical Characteristic Parameter
2.3.2.3.1
Power Supply DC (not intrinsically safe)
Terminal no.: 16, 17
U
n
= DC 19.2 … 52.8 V
U
m
= DC 53 V
I
sc
= 100 A
For this connection cables with a transversal section of 1.5 mm² to 4 mm² are
allowed to be used only.
2.3.2.3.2
Power Supply PoE according to IEEE 802.3 af (not
intrinsically safe)
Terminal no.: 11, 12, 14, 15
U
n
= DC 24 … 48 V
U
m
= DC 57 V
I
sc
= 100 A
For the LAN connection it is only allowed to use cables of the type CAT5e or higher.
To observe the EMC rules with netting shielded cables have to be used.
Note
Using a power supply via PoE it is only allowed to use the unused data cable pairs
of a 10/100 Mbit/s Ethernet cable for the power.
Содержание ExResistTel IP2/IP154
Страница 1: ...Explosion proof and weatherproof VoIP telephones Operating instructions FHF BA 9710 6 03 13 V9 4 4 ...
Страница 43: ...Manual ResistTel IP2 IP152 Page 43 ExResistTel IP2 IP154 Figure 9 Set View ...
Страница 44: ...Page 44 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 Figure 10 Inside View of Telephone upper Part ...
Страница 375: ...Manual ResistTel IP2 IP152 Page 375 ExResistTel IP2 IP154 9 Connect the device with the power supply again ...
Страница 385: ...Manual ResistTel IP2 IP152 Page 385 ExResistTel IP2 IP154 5 3 2 EC Type Examination Certificate ExResistTel IP2 IP154 ...
Страница 386: ...Page 386 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 ...
Страница 387: ...Manual ResistTel IP2 IP152 Page 387 ExResistTel IP2 IP154 ...
Страница 389: ...Manual ResistTel IP2 IP152 Page 389 ExResistTel IP2 IP154 5 3 4 Declaration of Conformity ExResistTel IP2 IP154 ...
Страница 390: ...Page 390 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 ...