Page 310
Manual
ResistTel IP2 / IP152
ExResistTel IP2 / IP154
will allow command executions only between 12:00 and 12:59 and 22:00 and 4:59
local time (on a 24h clock). Note that if the device has no time set (yet), all
command executions will be cancelled.
If the /initial parameter is set, then no commands will be executed within the first
<minutes> minutes after the device has been booted. This is done to avoid firmware
download and flashing when installing devices.
mod cmd UP1 times /allow 12,22,23,0,1,2,3,4 /initial 6
will suppress any command file processing within the first six minutes after each boot
of the device. If /initial is set, for new devices (or those that have been reset to
factory settings), the command file will be retrieved even if it normally would be
suppressed by the /allow parameter. This allows new devices to retrieve a site
specific standard configuration quickly.
4.9.3.1.8
Prot Command
To initiate a firmware update, the following command can be executed:
mod cmd UP0 prot <url> <final-command> <build-serial>
This command downloads new firmware (if available) from the specified URL onto
the device. Finally, the <final-command> is executed. The phone has an internal
variable that is initially empty (or empty if the device was reset with the standard
settings) called UPDATE/PROT. The prot command compares the content of <build-
serial> with the UPDATE/PROT variable. If both match, no firmware is downloaded.
If the UPDATE/PROT variable is not set (new devices or after a device restart), the
content of <build-serial> is compared with the built number of the current firmware.
Once the firmware has been successfully downloaded, the UPDATE/PROT variable is
overwritten with the content of <build-serial>. Note that the <build-serial>
parameter is not compared with the firmware version currently loaded. It is the
responsibility of the administrator to keep this standard.
If the <url> parameter ends with a slash (‘/’), a standard firmware file name is
appended to the URL depending on the product description (for example, IP152.bin
for an IP system).
mod cmd UP0 prot http://192.168.0.10/firm/ip152.bin ireset 04-
5656
The command
mod cmd UP0 prot http://192.168.0.10/firm/ ireset 04-5656
Содержание ExResistTel IP2/IP154
Страница 1: ...Explosion proof and weatherproof VoIP telephones Operating instructions FHF BA 9710 6 03 13 V9 4 4 ...
Страница 43: ...Manual ResistTel IP2 IP152 Page 43 ExResistTel IP2 IP154 Figure 9 Set View ...
Страница 44: ...Page 44 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 Figure 10 Inside View of Telephone upper Part ...
Страница 375: ...Manual ResistTel IP2 IP152 Page 375 ExResistTel IP2 IP154 9 Connect the device with the power supply again ...
Страница 385: ...Manual ResistTel IP2 IP152 Page 385 ExResistTel IP2 IP154 5 3 2 EC Type Examination Certificate ExResistTel IP2 IP154 ...
Страница 386: ...Page 386 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 ...
Страница 387: ...Manual ResistTel IP2 IP152 Page 387 ExResistTel IP2 IP154 ...
Страница 389: ...Manual ResistTel IP2 IP152 Page 389 ExResistTel IP2 IP154 5 3 4 Declaration of Conformity ExResistTel IP2 IP154 ...
Страница 390: ...Page 390 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 ...