determines whether the DECT radio code PCS04fd was already installed. If this is not
the case, the current DECT radio code is downloaded from the address
192.168.0.10/firm/ccfp1200.bin, the UPDATE/BMC internal variable is overwritten
with PCS04fd and, finally, the device is reset as soon at it is not being actively used.
4.9.3.1.11
SCFG Command
mod cmd UP0 scfg
<url>
[
<final-command>
<save-serial>
[
/force
<hours>
]]
This will cause the device to upload its current configuration to <url>. This will be
done using an HTTP PUT command. <url> must be writable thus. Within <url>,
some meta character strings are replaced as follows:
Sequence Replacement
Example
#F
kernel build number
09-7030014
#fn
first n digits of kernel build number after the dash
70300
#B
boot code build number
09-7030012
#H
hardware build number
102
#h
device hardware ID
IP152-03-0d-f0
#n
device name
RadioOne
#m
MAC address of the device
00-50-c2-6a-50-01
#d
current date and time
20051010-170130
#bn
rolling backup index
3
#i
(one of) the local ip-address(es)
192.168.0.1
#N
network (that is, IP address with host bits set to 0) 192.168.0.0
#t
device type
IP152
##
escapes a hash mark
#
This meta character strings are available in the URL of SCFG command and in the
Update Server URL only.
The rolling backup index loops over 0 .. n-1 for each backup and can only be used
once in an update script. That means more than one SCFG command in a script with
a usage of the rolling backup index will overlap and produce unexpected results.
Beginning with V7.00 the optional Parameters <final-command>, <save-serial> and
/force <hours> will be recognized.
<final-command> defines the command to be executed after successful completion
of scfg (typically no-op is used).
<save-serial> is compared to the UPDATE/SCFG variable. If it is not equal, the
command is started. If it is equal and /force is not specified the command is skipped,
otherwise /force is evaluated.
Содержание ExResistTel IP2/IP154
Страница 1: ...Explosion proof and weatherproof VoIP telephones Operating instructions FHF BA 9710 6 03 13 V9 4 4 ...
Страница 43: ...Manual ResistTel IP2 IP152 Page 43 ExResistTel IP2 IP154 Figure 9 Set View ...
Страница 44: ...Page 44 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 Figure 10 Inside View of Telephone upper Part ...
Страница 375: ...Manual ResistTel IP2 IP152 Page 375 ExResistTel IP2 IP154 9 Connect the device with the power supply again ...
Страница 385: ...Manual ResistTel IP2 IP152 Page 385 ExResistTel IP2 IP154 5 3 2 EC Type Examination Certificate ExResistTel IP2 IP154 ...
Страница 386: ...Page 386 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 ...
Страница 387: ...Manual ResistTel IP2 IP152 Page 387 ExResistTel IP2 IP154 ...
Страница 389: ...Manual ResistTel IP2 IP152 Page 389 ExResistTel IP2 IP154 5 3 4 Declaration of Conformity ExResistTel IP2 IP154 ...
Страница 390: ...Page 390 Manual ResistTel IP2 IP152 ExResistTel IP2 IP154 ...