3. Installation
3-26
Festo P.BE-SPC11-SYS-ASI-EN en 0203NH
Please note
Check within the framework of your EMERGENCY STOP
circuit, to ascertain the measures necessary for putting
your machine/system into a safe state in the event of an
EMERGENCY STOP (e.g. switching off the operating volt-
age, switching off the compressed air).
Seal open cable ends, e.g. with cable cap type ASI-KK-FK from
Festo. In this way you will avoid leakage currents and comply
with protection class IP65.
Please note with branch lines:
– The total maximum length of the AS-Interface bus:
100 m incl. branch lines (without repeater/extender).
– The length of the cable for the operating voltage connection:
depends on the current consumption and the fluctuations
in the operating voltage.
Pin assignment of the bus connection and the oper-
ating voltage connection
The following are supplied with + 24 V DC via the operating
voltage connection marked with “24 V DC”:
– the operating voltage for the internal electronics of the
SPC11.
– the load voltage for the connected proportional direc-
tional control valve type MPYE-... and the measuring
system.
Содержание Soft Stop SPC11 Series
Страница 2: ......
Страница 14: ...Contents and general instructions XII Festo P BE SPC11 SYS ASI EN en 0203NH ...
Страница 15: ...Summary of components 1 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 1 ...
Страница 25: ...Fitting 2 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 2 ...
Страница 26: ...2 Fitting 2 2 Festo P BE SPC11 SYS ASI EN en 0203NH Contents 2 Fitting 2 1 2 1 Fitting the SPC11 2 3 ...
Страница 28: ...2 Fitting 2 4 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Страница 29: ...Installation 3 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 3 ...
Страница 61: ...Commissioning 4 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 4 ...
Страница 100: ...4 Commissioning 4 40 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Страница 101: ...Diagnosis and error treatment 5 1 Festo P BE SPC11 SYS ASI EN en 0203NH Chapter 5 ...
Страница 114: ...5 Diagnosis and error treatment 5 14 Festo P BE SPC11 SYS ASI EN en 0203NH ...
Страница 115: ...Operating the SPC11 in accordance with slave pro file 7 4 A 1 Festo P BE SPC11 SYS ASI EN en 0203NH Appendix A ...
Страница 127: ...Technical appendix B 1 Festo P BE SPC11 SYS ASI EN en 0203NH Appendix B ...