EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
68 (200)
The following table gives a list of the additional site specific information required to
configure the POTS cards, without this information commissioning cannot
commence. This information is provided in the CWA “DLE planning” spreadsheet,
produced by CWA DLE Management.
CWA “DLE planning”
Ref.
Comissioning
Procedure/LCT
Ref.
Example / Comments
H248 Virtual Gateway
4 digit domain name.
H248 Virtual
Gateway 4 digit
Domain Name.
eg 0016-CLNEW (New Cross). This is
site specific and will be supplied by
C&W. Usually the same value as used
by the EDA2510
Primary Media
Gateway Controller
Domain name
Primary Media
Gateway
Controller
Domain name
eg iMSS-BULLDOG-01 This may be
regional and must be supplied by C&W.
Primary Media
Gateway Controller
IP Address
Primary Media
Gateway
Controller IP
Address
eg 83.146.63.27 (The MGWC IP
Address). This is Media Gateway
specific and must be supplied by C&W.
H.248 S-VLANS (/23
subnets
RTP Local IP
Address
Each POTS card has a unique site
specific IP Address.
POTS Card S-VLAN
ID
POTS Card S-
VLAN ID
Slot 3 = 151, Slot 5 = 152, Slot 7 = 153,
Slot 9 = 154, Slot 11 = 155, Slot 13 =
156, Slot 15 = 157, Slot 17 = 158, Slot
19 = 159, Slot 21 = 160
Perform all of this section to configure the EDA 2530 Common Part IP card from the
LCT.