EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
80 (200)
Store the S-VLAN Table as follows:
a.
In the “
Ne Name”
column the template will load the default OOB IP
address of 150.150.150.4, the Node being commissioned is likely to have a
different one allocated to it. The Out Of Band IP Address is determined by
the DLE ID, refer to Section 5.5. Change the address (if necessary) in this
column for all entries, as follows:-
Change the 1
st
entry in this column to the correct IP address, select the 1
st
entry, then left-click the 1
st
entry & drag down to the bottom of the column
to highlight all entries. Right click & select “
Replicate cell
”, all entries in the
“
Ne Name”
column will now be set to the required OOB IP Address.
b.
In the “
S-VLAN ID”
column, the three “
Data-Inband”
entries will be loaded
with the default value of 22, check with the CWA “DLE planning” document
what the S-VLAN ID value should be set to for the node being
commissioned. This value will be either 21 or 22.
In the “
S-VLAN ID”
column change if necessary the value of these three
entries, to
21
or
22
as appropriate.
c.
In the “
Command
” column, in the 1
st
entry double click the empty field and
select the “
addPort
” option from the drop-down list. Select the 1
st
entry, left
click & drag down to the bottom of the column to highlight all entries. Right
click & select “
Replicate cell
”, all entries in the “
Command”
column will
now be set to “
addPort
”.
d. Select
“
Apply All
” from the bottom LHS of the screen. The rows will turn
Green and under the “Result” column the field should display “
OK
”.
e. Select
“
Read Network
” near the top of the screen, this will confirm the
configuration, if there are any incorrect entries they will be highlighted at
this point. Refer to the following screen.