EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
70 (200)
Check from the table that the SFP parameters are correct with the type of
module(s) installed, check that each SFP is alarm free, ie the Alarm Status
is ‘
not alarmed
’.
If the EDA 2530 “Parent” is to subtend an existing EDA 2510, then the
backhaul SFP1 module won’t be available at this Commissioning
stage (will be available when the two node types are migrated). Even
though SFP1 is not physically present continue to provision the CP
Port 1 interface as detailed in the following steps:-
c.
From the “CP-IP SFP/Port Provisioning” window select the row for CP Port
“
1/1/2/1
”.
d.
Click on the “
View Details/Modify selected SFP configuration
” button.
The following window will be displayed:-
e.
Leave “SFP MONI-tagged required” set to
true
(default).
Change “SFP Frame Type” to
Eth1000
.