EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
131 (200)
7.17.8
Step 7: Configure POTS Cards
a.
From the main LCT screen, right click on the 1
st
POTS card and select
“
Lines
” from the list of options. In the new window click on “
Configure
” to
view the current port configurations.
The “POTSx64 Lines Configuration” screen for
Line 1
will be displayed.
b.
In the AC profile field select from the drop-down list. For the UK select:-
“
1: BT-87+229//28.4nF+1052//228nF
” option
c.
In the DC profile field select from the drop-down list. For the UK select:-
“
1: 25mA_curr_limit
” option.
d.
In the “Metering Profile” field select from the drop-down list. For the UK
select “
1:Met BT 12K
” option.