EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
173 (200)
d.
In the TAM Connection Module section select
~
Inward (Interface) Test
radio button. Then click on the
Apply
button, and click on
Yes
on the
warning message.
e.
Check that the “Current relays position” box displays “
Inward Test
”.
f.
Click on the
Refresh
button, the radio buttons will be unselected.
g.
In the TAM Connection Module section select
~
Normal Operation
radio
button, then click on the
Apply
button. Click on
Yes
on the warning
message.
h.
Check that the “Current relays position” box displays “
Normal Operation
”.
i.
Click on the
Refresh
button, the radio buttons will be unselected.
j.
In the TAM Connection Module section select
~
Outward (Line) Test
radio
button. Click on the
Apply
button and click on
Yes
on the warning
message.
k.
Check that the “Current relays position” box displays “
Outward Test
”.