EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
29 (200)
Interconnection Cables for ITAM Connection Unit (02HAT00282AAQ)
Connect the NX Test cable to upper Line Test Access socket on slot 2 and 3 unit.
Connect RJ45 to RJ45 cable from lower Line Test Access socket on slot 2 and 3
unit to lower Line Test Access socket on slot 4 and 5 unit. Connect upper LTA
socket on slot 4 and 5 unit to upper LTA socket on slot 6 and 7 unit and repeat to
daisy chain each unit into the Test Bus.
Figure 2.13 – ITAM Connection Unit (02HAT00282AAQ) Interconnection
On a two EDA shelf site, connect RJ45 to RJ45 cable from the upper LTA socket on slot 20
and 21 unit on the fully equipped Lower shelf, to the upper LTA socket on slot 2 and 3 unit
on the Upper shelf. On the Upper shelf, connect RJ45 to RJ45 cable between the Line Test
Access sockets to daisy chain each unit into the Test Bus.
DESCRIPTION
CABLE CODES
DESCRIPTION
1HAU62575AAV
50mm LT Bridging cable between adjacent
COMBO cards (terminated with RJ45 plugs)
06ZZ7050
10m STP CAT5E LT cable to connect to
previous subrack (requires terminating with
RJ45 plugs)
LT Cables (ITAM)
2 x 46CJ9002
RJ45 Plugs for LT cable
NxTest
Upper
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Lower
2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21
NxTest
Upper
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Lower
2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21