EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
©
Ericsson AB 2010
Commercial in confidence
167 (200)
b. Set
the
Slot:
box to the SHDSL card slot to be re-enabled.
c. Select
the
~
Enable
radio button.
d.
Click on the
GO
button. Wait for all 32 lines to be enabled.
e.
Check the result is Found (Configured); 32 Updated: 32 Failed: 00.
If there are any failures click on the
View Error Log
button and read the
display. Any disabled lines will have to be enabled manually.
f. Select
the
~
Check
radio button.
g.
Click on the
GO
button. Wait for all 32 lines to be checked.
h.
Check the result is Found (Configured); 32 Enabled: 32 Disabled: 00.
If there are any lines Disabled, click on the
View Error Log
button and read
the display. Any disabled lines will have to be enabled manually.
9.2.1.4
Enable or Disable an SHDSL Line Manually (For Reference Only)
This Section is only required if an SHDSL line needs to be manually Enabled or
Disabled.
a.
Place the cursor on the <
32 x SHDSL unit >
to be configured.
b.
Right click on the unit and select
Lines
from the menu.