Installation 2. Installation
RC700-D Rev.2
17
-
Ensure the air flow around the supply and exhaust ports, and install the Controller
while leaving space from other equipment or walls as below.
* Keep the space about 200 mm or more on the top to maintenance.
(A)Flat mounting, (C)Rack mounting
100 mm
200 mm
Excluding the installation side
such as base table.
Air flow of the fan
50 mm
50 mm
50 mm *
(Figure Flat mounting)
(B)Upright mounting
100 mm
200 mm
Excluding the installation side such as base table.
Air flow of the fan
50 mm
50 mm *
50 mm
- Hot air with higher temperature than the ambient temperature (about 10
°
C) comes out
from the Controller. Make sure that heat sensitive devices are not placed near the
outlet.
- Arrange the cables in front of the Controller so that you can pull the Controller forward.