Regular Inspection 3. Alarm
RC700-D Rev.2
181
3. Alarm
When the batteries (lithium batteries) drain, an alarm warning voltage reduction occurs.
However, the alarm does not guarantee the battery lives until replacement, and it is necessary
to replace the batteries immediately. If you run out the batteries, the robot parameters will
be lost and recalibration of the robot will be required.
In addition, the parts for the Manipulator joints may cause accuracy decline or malfunction
due to deterioration of the parts resulting from long term use. If the robot breaks down due
to deterioration of the parts, it will take significant time and cost for repair.
The following sections describe the alarm function which announces the following
maintenance timings in order to perform maintenance well ahead of time before the warning
error.
3.1 Maintenance
The recommended replacement time can be configured for the Controller batteries, robot
grease, timing belts, motors, reduction gear units, and ball screw spline units.
CAUTION
■
Make sure that the date and time on the Controller are set correctly.
The maintenance cannot function properly with improper date and time setting.
■
If the CPU board or CF is replaced, the maintenance information may be lost. When
you replaced these parts, confirm the date and time of the Controller and the
maintenance information.
Maintenance is enabled at shipment.
If enabled, the maintenance information for the battery, timing belts, motors, reduction gear
units, ball screw spline unit, and grease up will be configured automatically when the robot
is configured or changed.
Ball screw spline unit on the Joint # 3
When the robot is deleted from the configuration, the maintenance information will also be
automatically deleted.
For details on the robot configuration, refer to
the EPSON RC+ 7.0 User’s Guide 10.1
Setting the Robot Model
.
CAUTION
■
Changing of the robot should be done carefully. The alarm setting will be reset when
the robot is changed.
The robot maintenance information depends on the Controller where the robot is configured
to. If the robot is replaced with the other robot with a different serial number, the
maintenance information will not function properly. When you replace the robot, edit the
maintenance information.
For details on the maintenance information editing, refer to
3.3 How to Edit the Maintenance
Information
.
NOTE
NOTE
Содержание RC700-D
Страница 1: ...Control Unit RC700 D Original instructions Rev 2 EM221C5146F ROBOT CONTROLLER RC700 D Manual ...
Страница 2: ...ROBOT CONTROLLER RC700 D Manual Rev 2 ...
Страница 8: ...vi RC700 D Rev 2 ...
Страница 16: ...Table of Contents xiv RC700 D Rev 2 ...
Страница 18: ......
Страница 80: ...Installation 5 Second Step 64 RC700 D Rev 2 ...
Страница 82: ......
Страница 87: ...Functions 1 Specifications RC700 D Rev 2 71 1 3 Outer Dimensions Unit mm ...
Страница 182: ...Functions 14 Option Slots 166 RC700 D Rev 2 14 8 6 Circuit Overview EUROMAP67 Board EUROMAP67 Board System diagram ...
Страница 190: ......
Страница 202: ...Regular Inspection 3 Alarm 186 RC700 D Rev 2 ...
Страница 203: ...187 Appendix ...
Страница 204: ......