Functions 12. I/O Remote Settings
RC700-D Rev.2
127
Name
Default
Description
Input Acceptance Condition
(*1)
ALIVE
Not Set
Input signal for alive monitoring of the
Controller. Same signal as the input
will be output to ALIVE output. The
master equipment can perform alive
monitoring of the Controller by
switching the input periodically and
checking the output signal.
(*1) “AutoMode output” ON is omitted from the table. This is an input acceptance condition for all functions.
(*2) “Start input” executes Function specified by the following six bits: SelProg 1, 2, 4, 8, 16, and 32.
Function
SelProg1 SelProg2 SelProg4 SelProg8 SelProg16 SelProg32
Main
0
0
0
0
0
0
Main1
1
0
0
0
0
0
Main2
0
1
0
0
0
0
Main3
1
1
0
0
0
0
.
.
.
Main60
0
0
1
1
1
1
Main61
1
0
1
1
1
1
Main62
0
1
1
1
1
1
Main63
1
1
1
1
1
1
0=OFF, 1=ON
(*3) “NoPause task” and “NoEmgAbort task” do not pause.
For details, refer to EPSON RC+ 7.0
Online Help
or
Pause
in
SPEL
+
Language Reference
.
(*4) Turns OFF the I/O output and initializes the robot parameter.
For details, refer to EPSON RC+ 7.0
Online Help
or
Reset
in
SPEL
+
Language Reference
.
(*5) When multiple robots are connected to the controller, the values specified by “SelRobot1, 2, 4, 8, and 16”
correspond to the robot numbers.
Robot number
SelRobot1
SelRobot2 SelRobot4 SelRobot8 SelRobot16
0(All)
0
0
0
0
0
1
1
0
0
0
0
2
0
1
0
0
0
3
1
1
0
0
0
.
.
.
13
1
0
1
1
0
14
0
1
1
1
0
15
1
1
1
1
0
16
0
0
0
0
1
0=OFF, 1=ON
(*6) Initializes the robot parameter.
For details, refer to EPSON RC+ 7.0 Online Help or Motor in SPEL+ Language Reference.
(*7) For details, refer to EPSON RC+ 7.0 Online Help or MCal in SPEL+ Language Reference.
(*8) This is for experienced users only. Make sure that you fully understand the input specification before using.
CmdRunning output and CmdError output will not change for this input.
“NoEmgAbort task” will not stop by this input.
When the input changes from ON to OFF, all tasks and commands will stop.
Содержание RC700-D
Страница 1: ...Control Unit RC700 D Original instructions Rev 2 EM221C5146F ROBOT CONTROLLER RC700 D Manual ...
Страница 2: ...ROBOT CONTROLLER RC700 D Manual Rev 2 ...
Страница 8: ...vi RC700 D Rev 2 ...
Страница 16: ...Table of Contents xiv RC700 D Rev 2 ...
Страница 18: ......
Страница 80: ...Installation 5 Second Step 64 RC700 D Rev 2 ...
Страница 82: ......
Страница 87: ...Functions 1 Specifications RC700 D Rev 2 71 1 3 Outer Dimensions Unit mm ...
Страница 182: ...Functions 14 Option Slots 166 RC700 D Rev 2 14 8 6 Circuit Overview EUROMAP67 Board EUROMAP67 Board System diagram ...
Страница 190: ......
Страница 202: ...Regular Inspection 3 Alarm 186 RC700 D Rev 2 ...
Страница 203: ...187 Appendix ...
Страница 204: ......