Functions 14. Option Slots
RC700-D Rev.2
171
14.8.11 Emergency stop connecter Pin Assignments
(EUROMAP67 Board)
Emergency stop connecter (CN2) Pin Assignment table of the EUROMAP67 board.
Emergency stop connecter
(CN2) Pin No.
Signal Name
Function
1
ESW11
Emergency Stop switch
contact
2
ESW12
Emergency Stop switch
contact
3
Emergency Stop circuit 1+
4
ESTOP1-
Emergency Stop circuit 1-
5
Not Used
-
6
Not Used
-
7
SD11
Safety Door input 1
8
SD12
Safety Door input 1
9
24V
24V output
10
24V
24V output
11
24VGND
24VGND output
12
24VGND
24VGND output
13
Not Used
-
14
ESW21
Emergency Stop switch
contact
15
ESW22
Emergency Stop switch
contact
16
Emergency Stop circuit 2+
17
ESTOP2-
Emergency Stop circuit 2-
18
SDLATCH1
Safety Door Latch Release
19
SDLATCH2
Safety Door Latch Release
20
SD21
Safety Door input 2
21
SD22
Safety Door input 2
22
24V
24V output
23
24V
24V output
24
24VGND
24VGND output
25
24VGND
24VGND output
26
Not Used
-
Содержание RC700-D
Страница 1: ...Control Unit RC700 D Original instructions Rev 2 EM221C5146F ROBOT CONTROLLER RC700 D Manual ...
Страница 2: ...ROBOT CONTROLLER RC700 D Manual Rev 2 ...
Страница 8: ...vi RC700 D Rev 2 ...
Страница 16: ...Table of Contents xiv RC700 D Rev 2 ...
Страница 18: ......
Страница 80: ...Installation 5 Second Step 64 RC700 D Rev 2 ...
Страница 82: ......
Страница 87: ...Functions 1 Specifications RC700 D Rev 2 71 1 3 Outer Dimensions Unit mm ...
Страница 182: ...Functions 14 Option Slots 166 RC700 D Rev 2 14 8 6 Circuit Overview EUROMAP67 Board EUROMAP67 Board System diagram ...
Страница 190: ......
Страница 202: ...Regular Inspection 3 Alarm 186 RC700 D Rev 2 ...
Страница 203: ...187 Appendix ...
Страница 204: ......