Installation 2. Installation
RC700-D Rev.2
9
The table must be secured on the floor or wall to prevent it from moving.
The Manipulator installation surface should have a flatness of 0.5 mm or less and an
inclination of 0.5 ° or less. If the flatness of the installation surface is improper, the base
may be damaged or the robot may not fully show its performance.
When using a leveler to adjust the height of the base table, use a screw with M16 diameter.
Connector
If you are passing cables through the holes on the base table, see the figures below.
[unit : mm]
M/C Cable
Power Connector
Signal
Connector
M/C Cable Hood
54
35
49
11
82
44
Power Connector
(Straight)
Signal Connector
83
76
Power Connector
(L Shaped)
35
When using the Manipulator in the cleanroom, follow the steps below before the installation.
(1)
Unpack the Manipulator outside of the cleanroom.
(2)
Secure the Manipulator to delivery equipment such as a pallet with bolts so that the
Manipulator does not fall over.
(3)
Wipe off the dust on the Manipulator with a little alcohol or distilled water on a lint-
free cloth.
(4)
Transport the Manipulator into the cleanroom.
(5)
Secure the Manipulator to the base table.
Содержание RC700-D
Страница 1: ...Control Unit RC700 D Original instructions Rev 2 EM221C5146F ROBOT CONTROLLER RC700 D Manual ...
Страница 2: ...ROBOT CONTROLLER RC700 D Manual Rev 2 ...
Страница 8: ...vi RC700 D Rev 2 ...
Страница 16: ...Table of Contents xiv RC700 D Rev 2 ...
Страница 18: ......
Страница 80: ...Installation 5 Second Step 64 RC700 D Rev 2 ...
Страница 82: ......
Страница 87: ...Functions 1 Specifications RC700 D Rev 2 71 1 3 Outer Dimensions Unit mm ...
Страница 182: ...Functions 14 Option Slots 166 RC700 D Rev 2 14 8 6 Circuit Overview EUROMAP67 Board EUROMAP67 Board System diagram ...
Страница 190: ......
Страница 202: ...Regular Inspection 3 Alarm 186 RC700 D Rev 2 ...
Страница 203: ...187 Appendix ...
Страница 204: ......