Installation 2. Installation
RC700-D Rev.2
29
Pin Assignments
The EMERGENCY connector pin assignments are as follows:
Pin No.
Signal
Function
Pin No.
Signal
Function
1
ESW11
Emergency Stop switch
contact (1) *3
14
ESW21
Emergency Stop switch
contact (2) *3
2
ESW12
Emergency Stop switch
contact (1) *3
15
ESW22
Emergency Stop switch
contact (2) *3
3
Emergency Stop circuit
1 (+) *4
16
Emergency Stop circuit 2
(+) *4
4
ESTOP1
−
Emergency Stop circuit
1 (
−
) *4
17
ESTOP2-
Emergency Stop circuit 2
(
−
) *4
5
Not used *1
18
SDLATCH1 Safety Door Latch
Release
6
Not used *1
19
SDLATCH2 Safety Door Latch
Release
7
SD11
Safety Door input (1) *2
20
SD21
Safety Door input (2) *2
8
SD12
Safety Door input (1) *2
21
SD22
Safety Door input (2) *2
9
24V
+24V output
22
24V
+24V output
10
24V
+24V output
23
24V
+24V output
11
24VGND +24V GND output
24
24VGND
+24V GND output
12
24VGND +24V GND output
25
24VGND
+24V GND output
13
Not used
*1 Do not connect anything to these pins.
*2 A critical error occurs if the input values from the Safety Door 1 and Safety Door 2 are
different for two or more seconds. They must be connected to the same switch with
two sets of contacts.
*3 A critical error occurs if the input values from the Emergency Stop switch contact 1 and
Emergency Stop switch contact 2 are different for two or more seconds. They must
be connected the same switch with two sets of contacts.
*4 Do not apply reverse voltage to the Emergency Stop circuit.
Emergency Stop switch output rated load
+30 V 0.3 A or under
1-2, 14-15 pin
Emergency Stop rated input voltage range
Emergency Stop rated input current
+24 V
±
10%
37.5 mA
±
10% / +24V input 3-4, 16-17 pin
Safety Door rated input voltage range
Safety Door rated input current
+24 V
±
10%
10 mA / +24 V input
7-8, 20-21 pin
Latch Release rated input voltage range
Latch Release rated input current
+24 V
±
10%
10 mA / +24 V input
18-19 pin
The total electrical resistance of the Emergency Stop switches and their circuit should be 1
Ω
or less.
CAUTION
■
The 24 V output is for emergency stop. Do not use it for other
purposes. Doing so may result in system malfunction.
■
Do not apply reverse voltage to the Emergency Stop circuit.
Doing so may result in system malfunction.
NOTE
Содержание RC700-D
Страница 1: ...Control Unit RC700 D Original instructions Rev 2 EM221C5146F ROBOT CONTROLLER RC700 D Manual ...
Страница 2: ...ROBOT CONTROLLER RC700 D Manual Rev 2 ...
Страница 8: ...vi RC700 D Rev 2 ...
Страница 16: ...Table of Contents xiv RC700 D Rev 2 ...
Страница 18: ......
Страница 80: ...Installation 5 Second Step 64 RC700 D Rev 2 ...
Страница 82: ......
Страница 87: ...Functions 1 Specifications RC700 D Rev 2 71 1 3 Outer Dimensions Unit mm ...
Страница 182: ...Functions 14 Option Slots 166 RC700 D Rev 2 14 8 6 Circuit Overview EUROMAP67 Board EUROMAP67 Board System diagram ...
Страница 190: ......
Страница 202: ...Regular Inspection 3 Alarm 186 RC700 D Rev 2 ...
Страница 203: ...187 Appendix ...
Страница 204: ......