Hauser
Flow characteristic values in US units
Nominal diameter
Recommended
flow
Factory settings
Max. full scale value
Pulse value
Low flow cut off
(v ~ 0.13 ft/s)
[in]
[gal/s]
[oz fl]
[oz fl/s]
⁵⁄₃₂
0.035
0.0002
0.02
⁵⁄₁₆
0.13
0.001
0.08
½K
0.32
0.004
0.25
½
0.44
0.004
0.25
1
1.33
0.007
0.53
1)
Conical version (corresponds to DN 12)
Recommended measuring range
Operable flow range
Over 1000 : 1
16.4 Output
Output signal
Pulse/frequency/switch output
Function
Can be set to:
• Pulse
Quantity-proportional pulse with pulse width to be configured.
• Automatic pulse
Quantity-proportional pulse with on/off ratio of 1:1
• Frequency
Flow-proportional frequency output with on/off ratio of 1:1
• Switch
Contact for displaying a status
Channel 2
Redundant output of pulse output: 0°, 90° or 180°
Version
Passive, open emitter
Maximum input values
• DC 30 V
• 25 mA
Voltage drop
At 25 mA: ≤ DC 2 V
Pulse output
Pulse width
Adjustable: 0.05 to 3.75 ms
Maximum pulse rate
10
000 Impulse/s
Pulse value
Adjustable
Assignable measured
variables
Volume flow
Frequency output
Output frequency
Adjustable: 0 to 10
000 Hz
Damping
Adjustable: 0 to 999.9 s
Pulse/pause ratio
1:1
Assignable measured
variables
Volume flow