Dosimag
Technical data
Hauser
61
Switch output
Switching behavior
Binary, conductive or non-conductive
Number of switching
cycles
Unlimited
Assignable functions
• Off
• On
• Diagnostic behavior
– Alarm
– Alarm and warning
– Warning
• Limit value:
– Off
– Volume flow
– Flow velocity
• Status
Low flow cut off
Signal on alarm
Depending on the interface, failure information is displayed as follows:
Pulse/frequency/switch output
Pulse output
Failure mode
Choose from:
• Actual value
• No pulses
Frequency output
Failure mode
Choose from:
• Actual value
• 0 Hz
• Defined value: 0 to 10
000 Hz
Switch output
Failure mode
Choose from:
• Current status
• Open
• Closed
Low flow cut off
The switch points for low flow cut off are user-selectable.
Galvanic isolation
– Pulse/frequency/switch outputs galvanically isolated from supply potential.
– Pulse/frequency/switch outputs not galvanically isolated from each other.
16.5 Power supply
Terminal assignment
Pin assignment, device plug