Commissioning
Dosimag
36
Hauser
Measuring value at maximum
frequency
Failure mode
Failure frequency
Invert output signal
Parameter overview with brief description
Parameter
Prerequsite
Description
Selection / User
entry
Factory setting
Operating mode
–
Define the output as a pulse,
frequency or switch output.
• Off
• Pulse
• Automatic pulse
• Frequency
• Switch
•
Pulse/frequency/
switch output 1
submenu:
Pulse
option
•
Pulse/frequency/
switch output 1 to
2
submenu:
Switch
option
Assign frequency output
The
Frequency
option is
selected in the
Operating
mode
Select process variable for
frequency output.
• Off
• Volume flow
Off
Minimum frequency value
In the
Operating mode
parameter, the
Frequency
option is selected and in the
Assign frequency output
Volume flow
option is
selected.
Enter minimum frequency.
0.0 to 10
000.0 Hz
0.0 Hz
Maximum frequency value
In the
Operating mode
parameter, the
Frequency
option is selected and in the
Assign frequency output
Volume flow
option is
selected.
Enter maximum frequency.
0.0 to 10
000.0 Hz
10
000.0 Hz
Measuring value at maximum
frequency
In the
Operating mode
Frequency
option is selected
and in the
Assign frequency
output
the
Volume flow
option is
selected.
Enter measured value for
maximum frequency.
Signed floating-point
number
Depends on country
and nominal
diameter
Failure mode
In the
Operating mode
Frequency
option is selected
and in the
Assign frequency
output
the
Volume flow
option is
selected.
Define output behavior in
alarm condition.
• Actual value
• Defined value
• 0 Hz
0 Hz