Electrical connection
Dosimag
24
Hauser
7
Electrical connection
The measuring device does not have an internal circuit breaker. For this reason,
assign the measuring device a switch or power-circuit breaker so that the power
supply line can be easily disconnected from the mains.
7.1
Connection conditions
7.1.1
Requirements for connecting cable
The connecting cables provided by the customer must fulfill the following requirements.
Electrical safety
In accordance with applicable federal/national regulations.
Permitted temperature range
• –40 °C (–40 °F) to +80 °C (+176 °F)
• Minimum requirement: cable temperature range ≥ ambient tempe20 K
Signal cable
Cables are not included in the scope of delivery; they can be ordered as an accessory
Pulse/frequency/switch output
Standard installation cable is sufficient.
7.1.2
Terminal assignment