10.5. Safety
DC Input Protection
Max. Voltage ±100 V, limit > 100 VDC
Data Line Input Protection
Max. Voltage ±40 V, limit > 40 VDC
Over Temperature
NTC measurement on every connector
Over Current
Electronic protection on every switch
Current Measurement
Over current measurement at the output
10.6. Interfaces
Framebus
Function
Control Bus (Daisy Chain) through AutoWave
Master
AutoWave
Connector Type
15 pin D-Sub m/f
Monitor
Output
DUT out, differential
Connector Type
BNC on the front panel
Voltage Ratio
20:1
Bandwidth
10 MHz
10.7. Bus Systems (data lines)
CAN Bus
- Low Speed Can 100 kbit
- High Speed Can 500 kbit
LIN Bus
- LIN Bus 19200 Baud
FlexRay
- FlexRay 10 Mbit
10.8. General
Dimensions
19"/3 HU, 448 mm x 536 mm x 154 mm
Figure 10.1
Weight
12.6kg
Mains
100 V - 265 VAC, 50/60 Hz
Fuses
2 x 2 AT (5 x 20 mm)
10.9. Environmental
Operating Temperature
23 °C ±5 °C
Storage Temperature
10 °C to 35 °C
Relative Humidity
25 % to 75 %, non-condensing
Air Pressure
86 kPa (860 mbar) to 106 kPa (1,060 mbar)