AX100-Series - Installing a Fibre Channel Storage System with a Direct Connection to a NetWare Server
47
Initializing the Storage System
8. Using the information from the Storage-System Management
Ports section of the completed storage-system configuration
planning worksheet, follow the instructions on the screen to set
the following management user account settings for the storage
system.
9. When you have set the parameters to the values you want, apply
the values by typing
a
.
10. Exit the utility by typing
e
.
If you entered an SP IP address for the first time or changed an SP
IP address, the utility reboots the storage system and the
SP Boot/Fault light on the back of each SP starts blinking
(Figure 19). The reboot takes several minutes to complete. When
it is completed, the SP Boot/Fault light on each SP stops blinking
and remains off.
Figure 19
SP Boot/Fault and Power Supply Fault Lights (AX100 Shown)
User name
User name for the management port. A valid user name must
start with a letter, can contain only letters and numbers, cannot
exceed 32 characters, and is case sensitive. For example,
blindmice3
is a valid user name and is a different name from
BLINDMICE3
.
Password
Password for the user connected to the management port. A valid
password can contain only letters and numbers, cannot exceed
32 characters, and is case sensitive. For example,
mousetrap2
is
a valid password and is a different password from
MOUSETRAP2
.
Confirm password
Previously entered password for password verification.