AX100-Series - Installing a Fibre Channel Storage System with a Direct Connection to a NetWare Server
11
Installing PowerPath on the Server
When the system prompts you to install software from the
selected path or specify a different one:
• If you selected
EMC_PP_305:\NetWare
in the previous step,
press
Enter
to install from that path.
• If you did
not
select
EMC_PP_305:\NetWare
in the previous
step, press
F3
and when prompted to specify a directory path,
enter
emc_pp_305:\netware
7. At the
PowerPath Installation Script
menu, select
Install/Upgrade PowerPath Driver
.
The installation script copies the driver to the system and then
opens the
EMC PowerPath Registration Utility
screen.
8. At the prompt
Do you have a new registration key or keys
to enter?[n]
, type
n
and press
Enter
.
You see this message:
License registration is NOT required to manage the
CLARiiON AX series array
.
The system prompts you for the type of reboot.
9. Select
Shut Down
to shut down and power off the server.
10. Power up the server.
CAUTION
!
If you use the server -ns command to bring up NetWare, you must
either load the PowerPath driver manually or remove all redundant
paths. Failure to do so may result in virtual disk corruption.