10
AX100-Series - Installing a Fibre Channel Storage System with a Direct Connection to a NetWare Server
Installing PowerPath on the Server
Install PowerPath on the Server
1. Insert the PowerPath installation CD in the CD drive.
2. At the console prompt, type
cdrom
and press
Enter
to mount the
CD.
3. Make sure the
SCSISAN.CDM
module is not installed:
a. At the console prompt, type
NWCONFIG
b. At the
Configuration Options
main menu, select
NCF Files
Options
.
c. Select
Edit STARTUP.NCF File
d. When the system prompts you to specify the server boot path,
press
Enter
.
e. If
SCSISAN.CDM
is listed, comment it out.
f. Press F10 to return to the C
onfigurations Options
main menu.
4. At the
Configuration Options
main menu, select
Product Options
and press
Enter.
5. At the
Other Installation Actions
window, select
Install a not listed
and press
Enter
.
A
Previously Specified Paths
window opens. If you have
previously installed PowerPath 3.0.x, this window lists the CD
path, which is one of the following:
•
EMC_PP_300:\Netware
— PowerPath 3.0.0 (Enterprise or
Enterprise Plus)
•
EMC_PP_302:\Netware
— PowerPath 3.0.2 (Base)
•
EMC_PP_303:\Netware
— PowerPath 3.0.3
•
EMC_PP_305:\Netware
— PowerPath 3.0.5
6. If
EMC_PP_305:\NetWare
is listed in the
Previously Specified
Paths
window, select it; otherwise, select any path, and press
Enter
.