AX100-Series - Installing a Fibre Channel Storage System with a Direct Connection to a NetWare Server
Initializing the Storage System
Run the Navisphere Storage System Initialization Utility on a NetWare Client
1. From the
Uninitialized Systems
list, select the storage system
and click
Next
.
2. Using the information from the Storage-System Management
Ports section of the completed storage-system configuration
planning worksheet, enter the following network parameters for
the storage-system 10/100
management
ports, and click
Next
:
3. Enter the name you want for the storage system, which cannot
exceed 32 characters.
4. Using the information from the Storage-System Management
Ports section of the completed storage-system configuration
planning worksheet, enter the following management user
account settings for the storage system:
5. Click
Next
to view the summary of the management user account
settings for storage system.
6. If the settings are correct, click
Finish
.
Storage Processor A - IP
IP address for SP A management port.
Storage Processor B - IP
IP address for SP B management port.
Subnet Mask
Subnet mask associated with the LAN to which the
storage-system management port is connected.
Default Gateway
Default gateway address for the LAN to which the
storage-system management port is connected.
User name
User name for the management port. A valid user name must
start with a letter, can contain only letters and numbers, cannot
exceed 32 characters, and is case sensitive. For example,
blindmice3
is a valid user name and is a different name from
BLINDMICE3
.
Password
Password for the user connected to the management port. A valid
password can contain only letters and numbers, cannot exceed
32 characters, and is case sensitive. For example,
mousetrap2
is
a valid password and is a different password from
MOUSETRAP2
.
Confirm password
Previously entered password for password verification.