AX100-Series - Installing a Fibre Channel Storage System with a Direct Connection to a NetWare Server
41
Initializing the Storage System
Figure 16
Storage-System Lights (LEDs)
2. Start the Navisphere Storage System Initialization Utility by
clicking
Start > Programs > EMC > Navisphere > Navisphere
Storage System Initialization
.
3. Read the license agreement and click
I accept
and
Next
.
The utility automatically scans the subnet for AX100-Series
storage systems. When this storage-system discovery operation is
complete, the utility lists, by hardware serial number, all
uninitialized and initialized storage systems it discovered. The
hardware serial number is on a label on the rear of the chassis
(see page 39).
If the storage system you are installing was not discovered, verify
the cable connections between the storage system and the
computer running the utility.
FE 0
FE 1
FE 0
FE 1
Power
SP A Boot/Fault
Power Supply A Fault
Power Supply B Fault
SP B Boot/Fault
EMC2928d
SP B
SP A
Rear Lights
Fault
Disk Activity
EMC2934
Power
Front Lights