AX100-Series - Installing a Fibre Channel Storage System with a Direct Connection to a NetWare Server
33
Connecting ac Power to an AX100 Storage System
Connect the UPS Serial Cable to the AX100 Storage System
CAUTION
!
Be sure to use the unique serial cable supplied with your UPS; a
standard null-modem or other service serial cable may look
identical, but will not work. You may need to attach an adapter
cable to connect the UPS serial cable to the AX100 UPS port.
If the UPS serial cable has two DB9 connectors
:
1. Locate an RJ45-DB9 adapter cable in the AX100-Series accessory
box.
2. Plug the adapter cable into the UPS serial cable.
3. Plug the free end of the UPS serial cable into the serial port on the
UPS (Figure 13).
4. Plug the free end of the adapter cable into the UPS connector
(labeled with a +- battery icon) on SP A (Figure 13).
If the UPS serial cable has one DB9 and one RJ45 connector:
1. Plug one end of the UPS serial cable into the serial port on the
UPS (Figure 13).
2. Plug the free end of the UPS serial cable into UPS connector
(labeled with a +- battery icon) on SP A (Figure 13).