Electrical Installation
Operating instructions RLD 73
ELTROPLAN
-
REVCON
Elektrotechnische Anlagen GmbH
Terminals 1-4 (refer to figure 4.4.4.2)
These terminals are contacted to two potential free (SELV) relay contacts (one NOC and
one NCC) with a maximum current load of 5 A AC or 3 A DC. It is not allowed to con-
nect other voltage types than SELV!
In figure 4.4.4.2 the relay is displayed in rest position.
The relay toggles, if:
1.) Power supply is o.k.
2.) No error present, and after perhaps an
ON
-signal has been released.
If an
OFF
-signal has been released, a collective error is display as the relay toggles.
Terminals 5 and 6
These terminals are already used for the internal temperature supervision of the heat sink.
Terminals 7 and 8
(Use screened wires only, maximum length)
OFF
-signal
These terminals may be used for an external
OFF
-signal (NOC, short time contact) to
stop the power feedback unit.
Note!
The OFF-signal stops the feed back immediately. If this is done in regent mode, the controller
would trip because of too high DC-bus voltage right afterwards.
Terminals 9 and 10
Not used
Terminal 11 and 12
(Use screened wires only)
These terminals may be used for an external
ON
-signal (external voltage 12 – 24V DC
[e.g. from PLC], short time pulse) to start / reset the power feedback unit.
(Connect „Plus“ to terminal 11, „Minus“ to terminal 12)
Содержание REVCON RLD
Страница 46: ...Installation Operating instructions RLD 45 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 2 Enclosure 0 340 ...
Страница 47: ...Installation 46 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 3 Enclosure 0 341 ...
Страница 48: ...Installation Operating instructions RLD 47 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 4 Enclosure 0 400 ...
Страница 49: ...Installation 48 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 5 Enclosure 1 501 ...
Страница 50: ...Installation Operating instructions RLD 49 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 6 Enclosure 2 701 ...
Страница 51: ...Installation 50 Operating instructions RLD ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 7 Enclosure 3 800 ...
Страница 52: ...Installation Operating instructions RLD 51 ELTROPLAN REVCON Elektrotechnische Anlagen GmbH 8 Enclosure 3 801 ...